Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3869478 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Special Repair To Building No P-111/04 (b And C Coy), P-243 (single Offr Living) At Sri Ganganagar Mil Stn |
| Last Date For Submission | 25th Apr, 2026 |
| Opening Date | 27 Apr, 2026 |
| Document Cost | 1000.00 |
|---|---|
| EMD | 182990.00 |
| Estimated Cost | 0.00 |
| City | Ganganagar |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Dismatiling of existing roof treatment upto the roof slab including brick tiles/terracing tiles and mud phuska complete all as specified and directed by Engineer - in - Charge. | 805.00 | Sqm |
| 2 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm. (a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification. (b) Apply 1st coat of ShaliUrethane BTD (white) @ 650 gm / m (minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane BTD (white) @ 650 gm / m (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger Paints Note : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE. (iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. | 805.00 | Sqm |
| 3 | M&L for levelling course for roof slab, Type B0, 1:2:4 (12.5 mm graded aggregate) for maintaining proper roof slope, filling the depression and finishing cement concrete surface even and smooth without using extra cement complete all as specified. (Minimum thickness of concrete should not be less than 50 mm at any point). | 42.00 | Cum |
| 4 | Dismantling for floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer - in - Charge. | 662.00 | Sqm |
| 5 | M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15 mm thick screed bed in cm 1:6 complete all as specified and directed by Engineer - in - Charge. | 137.00 | Sqm |