BOQ Items
#ItemQtyUnits
1Taking down existing unserviceable BER Acs, Water Cooler and Refrigerators of any type and any capacity with all connected items complete after disconnecting the electric supply line and depositing at MES E/M store yard of GE Gangtok complete all as specified and as directed. .9.00Each
2Supply, install and commisioning of hi wall split AC Cooling & Heating function units indoor / outdoor, complete with cordless remote control unit, timer and with in built air ioniser and plasma filter for better indoor air quality, including suitable copper pipe from indoor unit to outerdoor unit, drain pipe from indoor unit to ground with minimum 5 STAR rating and ERE 3.51 capacity 1.5 tonnage complete all as specified and as directed. 17.00Each
3Supply, install and commisioning of hi wall split AC Cooling & Heating function units indoor / outdoor, complete with cordless remote control unit, timer and with in built air ioniser and plasma filter for better indoor air quality, including suitable copper pipe from indoor unit to outerdoor unit, drain pipe from indoor unit to ground with minimum 5 STAR rating and ERE 3.51 capacity 2 tonnage complete all as specified and as directed.5.00Each
4Supply, installation, testing and commissioning of Solar Hot Water System (Flat Plate Collector) based on indirect transfer of heat of capacity 200 LPD hot water storage tank shall be made out of SS with rock wool insulation of thickness 100 mm minimum including necessary fixing frame over the roof with electrical heating coil backup of 3KW heating coil and necessary thermostat etc complete all as specified and as directed as per following specifications:- (i) Solar flat plate collector with insulated outer metallic box covered on the top with glass sheet to collector system confirming to IS: 12933 (Pt-I). (ii) Absorber shall be metallic sheet with built in channels or riser tubes to carry water. (iii) sheet of absorber and absorber shall be made of copper.5.00Each
5Supply and installation,commissioning of water cooler fully stainless steel electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and as directed. 2.00Each