Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Public Works Department
Tender ID3944136
Organisation NamePublic Works Department
Tender BriefCorrigendum : Supply, Installation, Testing And Commissioning Of 250 Kva Diesel Generator Set And 250 Kva Transformer For Goa Samagra Shikhsa Building (old Scert) In Porvorim Constituency.
Last Date For Submission23rd Apr, 2026
Opening Date25 Apr, 2026
Cost
Document Cost10000.00
EMD139775.00
Estimated Cost6988751.00
Location
CityGoa
StateGoa

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply, Transportation, installation, testing and commissioning of silent Diesel Generator set of 250 KVA 415V, 1500 RPM, 0.8 power factor suitable for 50 Hz, 3-Phase system & for 0.85 load factor, 24V DC controlled voltage, model PKGBN-250, make PAI Kane or equvivalent or as per list of makes approved by the department, consisting of the following-(a) of approved fire retardant Acoustics enclosure and shall be sound proof, and specially designed to meet stringent MOEF / CPCB IV + norms, constructed out of 14 SWG or higher thickness CRCA sheet duly powder coated for long lasting service life and superior finish with hinged type doors with insulation. Alternator should be of stamford/Leyroy somer make or equvivalent or should be as per list of approved makes enclosed with class H or above type of insulation and brushless type of excitation type including all protections relays and having power efficiency of 0.8, 3 phase, 50 Hz, 415V with IP 23 protection,
2as approved by the engineer incharge, including Loading Unloading Charges and all Electrical permissions etc.at site as applicable.Engine should be of Baudouin / volvo eicher / cummins kirlosker etc. or equvivalent or as per list of makes approved by the department, Fuel tank of maximum 500 Ltrs capacity,
3AMF logic Control panel along with all the accessories such as change over switch etc. as per list of approved makes and as approved by the engineer incharge, the Radiator should be filled with sufficient level of coolant of appropriate viscosity.the protection system should be of appropriate quality lube oil of sufficient viscosity, Exhaust system with appropriate number and size of silencers and projected out as per standards laid down by MOEF / CPCB IV + norms for sound and Emission,cooling system shall be of water cooled or oil cooled as required, the battery charger and batteries should be of standard brands of 24V and 150AH etc. as required, breaker panel should include all necessary MCB's, MCCB's, Relays etc. of approved makes and as approved by the engineer incharge.1Nos
4Supply, Transportation, Erection, installation, testing and commissioning of 3 star, 3 phase 250KVA 11/0.433KV Copper wound Distribution transformer with Off circuit Tap Changer / OLTC etc . with HV & LV side cable box as per BIS 1180, level 2, AMD 4 including packaging and freight charges with latest Specifications and IS standards, etc. of make Digvijay, SVT or equvivalent and as per list of makes approved by the Department1Nos
5Supply & Laying of copper flexible cable for neutral connection of size 90sq.mm. As required and as per approved list of makes issued by the department.5Metre
23rd Apr, 2026

9 Days Left