Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4870314 |
|---|---|
| Organisation Name | Public Works Department |
| Tender Brief | Corrigendum : The Work Of Supply Installation, Testing, And Commissioning Of Air Conditioner And Electrical Supply System In Court And Rest Room Of District Judge And Additional District Judges In Honorable District Court Sant Kabir Nagar |
| Last Date For Submission | 3rd Aug, 2026 |
| Opening Date | 03 Aug, 2026 |
| Document Cost | 2354.00 |
|---|---|
| EMD | 703000.00 |
| Estimated Cost | 10062000.00 |
| City | Gorakhpur |
|---|---|
| State | Uttar Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU toODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase ACsupply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year OriginalEquipment Manufacturer (OEM) warranty both compressorand Printed Circuit Board (PCB). Must comply : Electricalcable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as perCPWD specification and IS : 1391 Part II 2023. The systemshall be able to operate up to 52 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating make:-O General/ Mitsubishi/ Daikin/ Hitachi/ Panasonic/ LG/ Carrier/ Blue Star/ Voltas. | 11 | Nos. |
| 2 | 2 TR with 5 Star BEE Rating | 44 | Nos. |
| 3 | SITC of 4 KVA Voltage Copper Wound Stablizer for Air Conditioner Upto 1.5TR (130-300 Range) (Make- V-Guard/microtek)/ Equivalent make as per direction of Engineer in charge. | 11 | Nos. |
| 4 | SITC 5 KVA Voltage Copper Wound Stablizer for Air Conditioner Upto 2TR (130-300 Range) (Make- V-Guard/microtek)/ Equivalent make as per direction of Engineer in charge. | 44 | Nos. |
| 5 | SITC of Suction/Discharge copper pipe line in split A.C. Unit 1.5 Ton Capacity including brazing, nitrile, rubber insulation 6mm thick class 'O' etc complete 1/4" (6.40 mm) and 1/2" (12.70 mm) complete in all respect. | 275 | Mtr. |
12 Days Left