Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4853801 |
|---|---|
| Organisation Name | Public Works Department |
| Tender Brief | Janpad Nyalaya Deoria Ke Family Court (criminal Court Building) Ke Nyalaya Kakshon Avam Vishram Kakshon Mein Ac Sthapna Ka Karya |
| Last Date For Submission | 18th Jul, 2026 |
| Opening Date | 18 Jul, 2026 |
| Document Cost | 854.00 |
|---|---|
| EMD | 227000.00 |
| Estimated Cost | 2273000.00 |
| City | Gorakhpur |
|---|---|
| State | Uttar Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering. All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only. Incoming: Incomer- 100 Amp- 1 Nos MCCB Outgoing- , 63 Amp - 2 Nos MCCB | 1 | Nos. |
| 2 | S&F of 100 Amp. 4 Pole Change Over Switch on 50mm x 50mm x 6mm angle iron frame, Including the cost of labour, T&P, Painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 800 Amp. 4 Pole on 50mm x 50mm x 6mm angle iron frame. | 1 | Nos. |
| 3 | Supplying and fixing following way, horizontal typethree pole and neutral, sheet steel, MCB distributionboard, 415 V, on surface/ recess, complete withtinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator).2.4.1 4 way (4 + 12), Double door | 4 | Nos. |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the 2X 6sq.mm+1X6sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | 500 | Mtr. |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | 150 | Mtr. |
11 Days Left