Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4633826 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair/maint To Sluice Valve , Nrv, Cleaning Of Ug Sump And Oh Tank, Centrifugal Pump Replacement, External Water Supply Pipe Line And Accessories Under Ge(af) Ta Gwalior |
| Last Date For Submission | 14th Jul, 2026 |
| Opening Date | 21 Jul, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 60000.00 |
| Estimated Cost | 3000000.00 |
| City | Gwalior |
|---|---|
| State | Madhya Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | M&L for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to GI strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, PCC chamber using PCC(1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed. Note :- (i) GI strip and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for PCC chamber and PCC cover as per SSR part-1. | 13.00 | Each |
| 2 | M&L in repair water level indicator gage of over head tank,replacement of copper float of size 200mm dia with 2mm thik flexible steel wire rope and replacement of level Scale painting of numbering, and replacement of gauge move pully complete accessory all as directed. | 3.00 | Each job |
| 3 | Supply fixing testing and commisioning of Automatic Star delta starter suitable for 15 HP, 3 Phase, 415 Volts motor including taking down old one complete all as specified and as directed by the Engineer-In-Charge. | 3.00 | Each |
| 4 | S&F in repair contactor 3 pole,32 Amps 415 Volts suitable for 12.5 HP Auto Star Delta Starter ,complete all as specified and as directed by the Engineer-In-Charge. | 3.00 | Each |
| 5 | S&F in repair Overload Relay of range 16 to 22 amps suitable for 3 Phase 15 HP Auto Star Delta Starter ,complete all as specified and as directed by the Engineer-In-Charge. | 4.00 | Each |