Tender BriefCorrigendum : Supplying Installation Testing And Commissioning Of 11000 433 Volts Outdoor Type Copper Wound 400 Kva Off Load Tap Changer Power Transformer At Telaiya Substation
Last Date For Submission5th May, 2026
Opening Date06 May, 2026
Cost
Document Cost5000.00
EMD33000.00
Estimated Cost1611314.00
Location
CityHazaribag
StateJharkhand

Register to see full details

BOQ Items
#ItemQtyUnits
1Supplying, Installation, Testing and Commissioning of 11000/433 volts, Outdoor type copper wound 400 KVA off load Tap Changer Power transformer at Telaiya sub- station
2Providing, erecting, testing and Commissioning of Power Transformer 11000/433 Volts, outdoor type copper wound 400 KVA off load tap changer transformer 12.5% to +2.5% as per IS:1180 (part I) :2014 Level II continuously rated for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45 by thermometer in oil and 50 by the resistance in winding after continuous run at full load rating, the transformer should have oil immersed winding having vector group DY 11, HT side connected in Delta and LT side connected in Star with neutral brought out connected to provided separate earthing. The transformer shall have power terminal arrangement, bushing/ cable end box on HT side and cable end box on LT side 2 nos. channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The Transformer should be of latest manufacturing standards as per amended IS specification and the Load & No load losses shall be as per IS. (1) Oil conservator with filling hole with cap and plain oil level gauge. (2) Silica gel dehydrating breather charged with silica gel. (3) Oil drain valve (4) Oil filter valve. (5) Lifting eys/ hooks. (6) Two earthing terminals. (7) Diagram and rating plate. (8) Air vent (9) Explosion vent (10) 100 mm dia thermometer with thermometer pocket. (11) four bi directional plain roller. Make- Kirlosker/BHEL/ABB/.1Job
3Cost towards making chemical earthing as per I:E Rules ,etc. all complete.2Job
4Supplying and fixing of 400 Amp. TP&N switch disconnector fuse unit in the existing metal board with ISI marked HRC fuse including drilling holes in metal board, making connection etc. as required.1Set
5Supplying &Laying XLPE / PVC insulated 300 mm 3.5 core Aluminium armoured cable 1.1 KV grade. Make- polycab/Havells/ KEI.from Transformer to panel board.20Mtrs.