Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4771641 |
|---|---|
| Organisation Name | Irrigation And Waterways Department |
| Tender Brief | Corrigendum : Renovation Work Of Boundary Wall At Seijberia Irrigation Sub-division Office Near Annex Building For A Length Of 30.00 M In Uluberia Municipality, P.s-uluberia, Ward No-21 District-howrah Under Rajapur Section Of Seijberia (i) Sub-division. |
| Last Date For Submission | 13th Jul, 2026 |
| Opening Date | 14 Jul, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 4499.00 |
| Estimated Cost | 224955.00 |
| City | Howrah |
|---|---|
| State | West Bengal |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Dismantling Brick/Tile Work Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specifications Clause 202 for Rural Roads of MORD. (i) Cement mortar. | 13.88 | Cum |
| 2 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. i) Pakur Variety | 1.25 | Cum |
| 3 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface (i) With 1:4 cement mortar (ii ) 20 mm thick plaster | 202.50 | Sqm |
| 4 | First class Brick Work in Cement and Sand mortar in steining of well, pier, abutment, wing wall, parapets, cross drain, H. P. culverts, guard wall etc. complete including cost and carriage of all materials. (i) With 1:4 cement mortar | 22.145 | Cum |
| 5 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curve dor straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (i) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge (ii) 25 mm to 30 mm shuttering without staging in foundation | 20.00 | Sqm |
5 Days Left