Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Nuclear Fuel Complex
Tender ID4386361
Organisation NameNuclear Fuel Complex
Tender BriefCorrigendum : Chemical Resistant Tiling, Specialized Floorings And Miscellaneous Civil Works At Various Areas Of Nfc Hyderabad.
Last Date For Submission17th Jun, 2026
Opening Date18 Jun, 2026
Cost
Document Cost0.00
EMD602000.00
Estimated Cost30100000.00
Location
CityHyderabad
StateTelangana

Register to see full details

BOQ Items
#ItemQtyUnits
1General Notes: 1) Item no. 1 to 5 shall be carried out by specialised agency having experience in chemical resistant tiling works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable. 2) Item no. 6 to 9 shall be carried out by specialised agency having experience in PU/epoxy/special flooring works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable. 3) The contractor shall follow relevant IS codes/technical specifications for execution of work. 4) The contractor shall maintain good workman ship and follow safe working procedures during the work. 5) Rates shall be inclusive of Scaffolding for all items for all heights and depths. 6) Before laying of chemical resiatnt tiling, PU flooring etc as per item no. 1 to 9, the condition and suitability of substrate shall be checked for recieving the tiling/flooring and if required suitable test shall be conducted for the asessing the condition and strength of substrate at no extra cost and as directed by EIC. 7) Contractor shall provide Distribution Board and 4C X16 sq.mm cable of required length at their own cost if required for obtaining temporary power supply from the department. The DB and power cable shall be as per the specifications of NFC. 8) Contractor shall fill the requisition form for providing temporary power supply and details of any equipment to be used at site (dewatering pump, cutting machine, drilling machines, etc) shall be indicated in the proforma annexed to requisition form. 9) Contractor shall employ a licensed electrician to carryout electrical connections /terminations, measurement of earth pit resistance, insulation resistance of their installation and intimating the same to the department & also earthing shall be ensured throught existance of power supply. Intimation shall be given after completion of work for disconnection of supply and safe isolation of DB with last energy meter reading.
2Providing corrosion resistant treatment to floors and wall by bitumen primer conforming to IS 158 with chemical resistant unpolished vitrified tiles of required thickness mentioned below confirming to IS:4457 (Endura of M/s.. H & R Johnson India limited) to resist corrosion action of nitric acid (HNO3) up to 60% concentration, caustic tlie 40% concentration, organic solvents (also to water in open areas which requires acid resistant polyester mortar), or any other chemical including preparing the surfaces, hacking and cleaning etc. complete as per specifications and as per IS 4457 : Latest Edition and as directed by engineer-in-charge to suit the above requirements and the thickness as mentioned below as per by manufacturer's recommendations, relevant standards and as directed by engineer-in-charge. Note: The work shall be carried out by specialised agency having experience in chemical resistant tiling works and the same shall be gotten approved by EIC before execution. The decision of EIC will be binding and non-arbitrable.
320 mm thick tiles of approved size and shade using potassium silicate bedding mortar as per IS:4832, curing the joints with 20 to 25% HCL, pointing the joints using carbon filled Sulphur cement in floors and with CNSL mortar in walls.530.00SQM
412 mm thick tiles of approved size and shade using potassium silicate bedding mortar as per IS:4832, curing the joints with 20 to 25% HCL, pointing the joints using carbon filled Sulphur cement in floors and with CNSL mortar in walls.620.00SQM
520 mm thick tiles of approved size and shade using CNSL bedding mortar and pointing the joints using Furane as per specified in IS:4832.20.00SQM