Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4386363 |
|---|---|
| Organisation Name | Nuclear Fuel Complex |
| Tender Brief | Corrigendum : Providing Polyethylene Glass Lining And Allied Works For The Existing Over Ground Solar Evaporation Pond (ogsep) At Nfc, Hyderabad. |
| Last Date For Submission | 17th Jun, 2026 |
| Opening Date | 18 Jun, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 304000.00 |
| Estimated Cost | 15200000.00 |
| City | Hyderabad |
|---|---|
| State | Telangana |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | General Notes: 1. The contractor shall follow relevant IS codes/technical specifications for execution of work. 2. The contractor shall maintain good workman ship and follow safe working procedures during the work. 3. Rates are inclusive of Scaffolding for all items for all heights. 4. Shuttering wherever required shall be carried out at no extra cost. 5. Leak test including filling of water and empty the tank (OGSEP) after test shall be carried out for the tank as per IS 3370 for requirements of watertightness, corrective action to ensure watertightness of the structure if any shall be done as per directions of EIC at no extra cost. 6. Removal of laitance/scales from OGSEP shall be done at no extra cost. 7. Contractor shall provide one nos of Construction Distribution board along with incoming power cable of required length (as per availability of nearest power source at site) as per NFC specifications for obtaining the temporary power supply for the works at no extra cost. 8. Contractor shall fill the requisition form for providing temporary power supply and details of any equipment to be used at site (dewatering pump, cutting machine, drilling machines, etc. shall be indicated in the proforma annexed to requisition form. 9. Contractor shall employ a licensed electrician to carryout electrical connections /terminations, measurement of earth pit resistance, insulation resistance of their installation and intimating the same to the department & also earthing shall be ensured throught existance of power supply. 10. Intimation shall be given after completion of work for disconnection of supply and safe isolation of DB with last energy meter reading. | ||
| 2 | Chipping of old unsound concrete surface to expose good concrete, removal of plaster if any, expose corroded reinforcements beneath unsound concrete to the extant of upto 100 mm in thickness including disposal of obtained debris within 50m lead, complete as directed by EIC. | 350.00 | Sqm |
| 3 | Injection Grouting using Cementitious grout admixed with SBR - Styrene Bitadiene Styrene Providing and Fixing 18mm/12 mm or any other dia GI/PVC nozzles (the nozzle shall be embedded about half the depth of the member to be grouted) in grid pattern at a spacing not more than 1m c/c along damaged/distressed area and in construction joints by drilling holes using drill machine and to be packed with polymer modified mortar of make Pidilite/Fosroc /SIKA/BASF/ Sunanda/ Krishna or any other approved equivalent make., grouting to be carried out with cement grout by mixing one bag of cement with one pouch of expansive plasticising admixture and 1 kg of SBR latex of make Pidilite (Dr Fixit Pidicrete AM and Dr fixit Pidicrete URP)/Fosroc or approved equivalent, removal of nozzles post grouting and plugging with Renderoc Plug of Fosroc or approved equivalent, complete as directed by EIC. (Record shall be maintained for number of grout holes and cement consumption in each hole) | 400.00 | Nos |
| 4 | Injection Grouting using Moisture Insensitive Epoxy Grout For strengthening the various members of the Concrete Segments, GI/PVC Nozzles shall be made in weak areas or at intervals of 1 metre centre to centre, and the same shall be injection grouted with Moisture Insensitive Epoxy Grout of Pidilite Industries Limited's make- Dr. Fixit Epoxy Injection Grout /equivalent material of Fosroc /SIKA/BASF/Sunanda/ Krishna or any other approved equivalent make. After the grouting is complete the nozzles shall be cut and the area shall be sealed with Renderoc Plug of Fosroc or approved equivalent, complete as directed by EIC. (Records shall be maintained for number of grout holes and material consumption in each grout point.) | 150.00 | kg |
| 5 | Cleaning Re-bars & Steel Surfaces Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of Pidilite Industries Limited's Dr. Fixit Rust Remover /equivalent material of Fosroc/ SIKA/BASF/Sunanda/ Krishna or any other approved equivalent make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. | 60.00 | litre |
6 Days Left