Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Kerala Water Authority
Tender ID2816285
Organisation NameKerala Water Authority
Tender BriefCorrigendum : Jjm- Wss To Chakkupallam, Vandanmedu, Karunapuram And Vandiperiyar Panchayats In Idukki District-supply Erection, Testing And Commissioning Of Raw Water And Clear Water Pump Sets And Transformers At Various Pump Houses Of The Scheme-general Civil Wor
Last Date For Submission26th Mar, 2026
Opening Date28 Mar, 2026
Cost
Document Cost11025.00
EMD200000.00
Estimated Cost96375526.00
Location
CityIdukki
StateKerala

Register to see full details

BOQ Items
#ItemQtyUnits
1Part -1-Supply, Erection, Testing and commissioning of Clear water Pump set from WTP - Amaravathi- Discharge 117lps, Head 105m
2OD80036/2024-2025:WTP-Amaravathy Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 117 lps<br>Total head - 105 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.3.000job
3Part-2 - Supply, Erection, Testing and commissioning of CF type CW Pumpsets from WTP to Ottakathalamedu - Discharge 56 lps, Head 55m
4OD80008/2024-2025:WTP-0ttakathalamedu Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge 56lps,Total head 55mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.2.000job
5Part -3-Supply, Erection, Testing and commissioning of CF type CW Pumpsets from station WTP - Spring Valley- Discharge 100 lps, Head 25m
26th Mar, 2026

20 Days Left