Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4748651 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair Maintenance Of Internal Wiring Distribution System Electrical Fitting Fixtures And Its All Allied Work Inside Area Of Sqae L Sqae A Cqa W And Cqa Ofv Of Dgqa Units Under Ge P No 1 Jabalpur |
| Last Date For Submission | 30th Jul, 2026 |
| Opening Date | 06 Aug, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 27700.00 |
| Estimated Cost | 1380038.00 |
| City | Jabalpur |
|---|---|
| State | Madhya Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed. | 527 | Per Point |
| 2 | Taking down carefully any type of old unserviceable submain wiring with PVC conduit surface / concealed or wooden battens etc and making good the disturbed surfaces to match with the existing surface complete all as specified & directed. | 300 | RM |
| 3 | Taking down old unserviceable DBs/Main switches any type/size complete with all accessories and remove from site complete all as specified & directed. | 34 | Each |
| 4 | M&L of Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 4 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run. | 200 | RM |
| 5 | M&L of Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run. | 100 | RM |
6 Days Left