Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4141166 |
|---|---|
| Organisation Name | Rajasthan Medical Services Corporation Limited |
| Tender Brief | Corrigendum : Short Term E-bid For Rate Contract Cum Supply And Empanelment Of Surgical Items |
| Last Date For Submission | 19th May, 2026 |
| Opening Date | 20 May, 2026 |
| Document Cost | 2360.00 |
|---|---|
| EMD | 882000.00 |
| Estimated Cost | 44100000.00 |
| City | Jaipur |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | "SyphilisAntibody (Rapid) detection kits 1. The assay should be based on Rapid chromatographic immunoassay for qualitative detection of Antibodies (lgG, lgA & lgM) to TP in serum, plasma & whole Blood. 2. The assay should utilize recombinant Treponemal antigens i.e. Tp15, Tpl7, Tp47 against Syphilis. 3. The assay should be in card format. 4. Adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit. 5. The kit should have approval of the statutory authority in its country of origin. 6. In case of imported kits it should be registered and licensed under the provisions of Drugs & Cosmetics act and rules and/or medical devices rules 2017 in India. 7. In case of indigenous manufacturers should be licensed under the provisions of Drugs & cosmetics Act and rules and or medical devices rules 2017 issued by the competent authority defined under Drugs and cosmetics act, 1940. 8. The kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees. 9. Read result time should not be more than 20 minutes. 10. Assay should have Sensitivity 100% & specificity 99 %or more with documentary evidence. 11. The storage & transport temperature of the Kit should be 2-30 C. 12. The pack size should not be more than 50 tests wherein each test is individually " | 800000 | pack size should not be more than 50 tests But rat |
| 2 | Bed Side Leucodepletion Filters for Blood Transfusion (For 2 unit of Red Cell) [NE32B] 1. Filters should be able to leucodeplete red cells form leukocyte contamination separately for 1 unit of red cells and for 2 units of red cells each. 2. Filters should be having the capacity of log 4 reduction (99.99%) 3. Filters should not carry any charges it should be neutrally charged. 4. Filters material should be polyester woven / non- woven. 5. Leukocytes should be consistently averaging less than 0.5x105 residual leucocytes for one unit of red cell and 0.2*106 for two units of red cell. RBC recovery should be averaging more than 90%. 6. Filters should have hard / soft housing for optical monitoring. 7. Filtration loss should not be more than 35 ml for one unit red cell. 8. Should have integrated 40 m, micro aggregate filter. 9. Should be US FDA/ European CE Certified. | 16500 | Filter should have individual packing with bulk bo |
| 3 | Hepatitis B Surface Antigen (Elisa) Testing Kits IV Generation/High sensitive Should have Microplate ELISA Coated with either polyclonal or monoclonal antibodies to HBsAg and either polyclonal or monoclonal antibodies in conjugate. The assay should be able to detect all the 11 subtypes (ad & ay subtype) including mutant strains. The assay should be able to detect surface antigen to hepatitis B virus. | 1221331 | 96 test/kit (kit containing 96 test) Rate should b |
| 4 | HBsAg (Rapid Test) | 1354052 | The pack size should not be more than 50 tests whe |
5 Days Left