Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Rajasthan Medical Services Corporation Limited
Tender ID4141166
Organisation NameRajasthan Medical Services Corporation Limited
Tender BriefCorrigendum : Short Term E-bid For Rate Contract Cum Supply And Empanelment Of Surgical Items
Last Date For Submission19th May, 2026
Opening Date20 May, 2026
Cost
Document Cost2360.00
EMD882000.00
Estimated Cost44100000.00
Location
CityJaipur
StateRajasthan

Register to see full details

BOQ Items
#ItemQtyUnits
1"SyphilisAntibody (Rapid) detection kits 1. The assay should be based on Rapid chromatographic immunoassay for qualitative detection of Antibodies (lgG, lgA & lgM) to TP in serum, plasma & whole Blood. 2. The assay should utilize recombinant Treponemal antigens i.e. Tp15, Tpl7, Tp47 against Syphilis. 3. The assay should be in card format. 4. Adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit. 5. The kit should have approval of the statutory authority in its country of origin. 6. In case of imported kits it should be registered and licensed under the provisions of Drugs & Cosmetics act and rules and/or medical devices rules 2017 in India. 7. In case of indigenous manufacturers should be licensed under the provisions of Drugs & cosmetics Act and rules and or medical devices rules 2017 issued by the competent authority defined under Drugs and cosmetics act, 1940. 8. The kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees. 9. Read result time should not be more than 20 minutes. 10. Assay should have Sensitivity 100% & specificity 99 %or more with documentary evidence. 11. The storage & transport temperature of the Kit should be 2-30 C. 12. The pack size should not be more than 50 tests wherein each test is individually " 800000pack size should not be more than 50 tests But rat
2Bed Side Leucodepletion Filters for Blood Transfusion (For 2 unit of Red Cell) [NE32B] 1. Filters should be able to leucodeplete red cells form leukocyte contamination separately for 1 unit of red cells and for 2 units of red cells each. 2. Filters should be having the capacity of log 4 reduction (99.99%) 3. Filters should not carry any charges it should be neutrally charged. 4. Filters material should be polyester woven / non- woven. 5. Leukocytes should be consistently averaging less than 0.5x105 residual leucocytes for one unit of red cell and 0.2*106 for two units of red cell. RBC recovery should be averaging more than 90%. 6. Filters should have hard / soft housing for optical monitoring. 7. Filtration loss should not be more than 35 ml for one unit red cell. 8. Should have integrated 40 m, micro aggregate filter. 9. Should be US FDA/ European CE Certified. 16500Filter should have individual packing with bulk bo
3Hepatitis B Surface Antigen (Elisa) Testing Kits IV Generation/High sensitive Should have Microplate ELISA Coated with either polyclonal or monoclonal antibodies to HBsAg and either polyclonal or monoclonal antibodies in conjugate. The assay should be able to detect all the 11 subtypes (ad & ay subtype) including mutant strains. The assay should be able to detect surface antigen to hepatitis B virus. 122133196 test/kit (kit containing 96 test) Rate should b
4HBsAg (Rapid Test)1354052The pack size should not be more than 50 tests whe
19th May, 2026

5 Days Left

WhatsApp