Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3822644 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Structural Audit Of Building In Zone-i Area Under Age B/r-i Of Ge Jaipur At Jaipur Mil Stn |
| Last Date For Submission | 21st Apr, 2026 |
| Opening Date | 23 Apr, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 19180.00 |
| Estimated Cost | 959000.00 |
| City | Jaipur |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Inspection and testing Non-Destructive Test (NDT Test) of buildings by site visit at each building location, investigating different part of buildings, preparation of preliminary data, conducting tests and formulating building wise test result and suggesting retrofitting/remedial measures and submission of report (in quadruplicate) with recommendation for strengthening of building with detailed drawings and BOQ (for repairing) or recommendation for demolition if not found structurally sound. | ||
| 2 | Rebound Hammer Test (RHT): - Test for determining the estimated compressive strength of concrete and uniformity of concrete in terms of surface hardness as per IS 13311(Part-2):1992, ASTM C 805-02, BS 6089:1981 and BS 1881: Part-202 :1986, BS EN 13791-2019; establishing correlation between rebound hammer and other confirmatory test for estimated in-situ strength of concrete as required and as directed. | ||
| 3 | Ultrasonic Pulse Velocity Test (UPVT): - For ascertaining the quality, soundness and density of concrete, uniformity of concrete in terms of density as per IS 13311 (Part-I) : 1992, ASTM C 597-83, BS 6089:1981 and BS 1881 : Part-203 and BS EN:13791, all as specified and directed. | ||
| 4 | pH Value and Carbonation Test: - Measurement of pH valve and carbonation depth by phenolphthalein spray indicator test at selected location of RCC members of the structures covered under the study to see the carbonation depth, cover depth shall also be measured to check the intensity of carbonation attach of steel, all as specified and directed. | ||
| 5 | Cover Meter Scanning or Rebar scanning Test: - Conducting cover meter test to locate the Re-bar alongwith its diameter at specified location of building under study as per standard engineering practice with latest available tools all as specified and directed. |
6 Days Left