Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Public Works Department
Tender ID4271066
Organisation NamePublic Works Department
Tender BriefRepairing Of Fire Detection System Of Ruhs Hospital Jaipur
Last Date For Submission21st May, 2026
Opening Date22 May, 2026
Cost
Document Cost500.00
EMD13020.00
Estimated Cost651000.00
Location
CityJaipur
StateRajasthan

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply, Installation, Testing & Commissioning of EN 54 certified Pannel controller to integrate with existing FAS Pannel with standard licence having LCD display (pixels) 7" color WVGA 800 x 480 with operating elements of 6 Keys and 18 LEDs with different interfaces CAN1, CAN2, ETH1, ETH2, ETH3, ETH4, USB , Rail for multi connectivity with IN1/IN2 signal input with IP 30 protection rating supports 1 USB function interface for remote configuration along with alarms indication having enough EROM to store up to 10,000 messages.1.00Each
2Supply, Installation, Testing & Commissioning of EN 54 certified battery control module with Two voltage outputs of 2.8 A at 24 V each, Temperature-controlled charging and monitoring of batteries according to EN 54 4:1997/A2:2006 having input voltage 20,4 V DC to 30 V DC supports different operating/display elements with Housing material ABS plastic, Polylac PA-766 (UL94 V 0) with voltage 2 outputs, switchable +24 V (20.4 - 30 V) 2,8 A battery-buffered (programmable) to be integrate with existing FAS system2.00Each
3Supply, Installation, Testing & Commissioning of EN 54 certified Color CAN Bus cable for connecting pannel controller with rail KITS, Power supply & BCM1.00Each
4Supply, Installation, Testing & Commissioning of EN 54 certified Loop Capacity module with Loop Capacity: Max 254 LSN improved elements / 127 LSN classic elements loop Current: Up to 300 mA. Operating Voltage: 30 V DC 1.0 V DC (LSN loop voltage). Line Length: Max 1600 meters (dependent on config/cable). Input Voltage: 24 V DC (via Fire Panel). Addressing: Supports auto-addressing (improved/classic) and manual addressing. Indicators: 2 LEDs (red = alarm, yellow = fault) with IP 30 rating to be integrate with existing FAS pannel with loop length capacity up to 1800 mtrs.5.00Each
5Supply, Installation, Testing & Commissioning of EN-54 certified Pannel long rail, Panel Rail Long shall be a modular mounting component designed for use within the existing Modular Fire Panel series. It must feature a four-slot capacity to accommodate up to four functional modules, providing both mechanical support and a high-speed internal bus for data and power distribution. The rail shall be constructed of durable, industrial-grade materials compatible with standard fire panel housings and must include the necessary data transmission cables for seamless connection to the panel controller or adjacent rails.4.00Each