Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4246160 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Comprehensive And Maint Of Sub Main Wiring, Dbs And Mcbs In Pocket No 05 To 15 At Zone-ii Under Ge (a) Jaisalmer At Mil Stn Jaisalmer |
| Last Date For Submission | 1st Jun, 2026 |
| Opening Date | 03 Jun, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 99000.00 |
| Estimated Cost | 4950000.00 |
| City | Jaisalmer |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge | 152.00 | Each |
| 2 | Taking down the existing unserviceable MCBs/MCCBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge | 860.00 | Each |
| 3 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLSH) in and including PVC casing & caping/Conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. Note: Two runs of 6.0 sqmm cable & One run of 6.0 sqmm cable and One run of PVC casing & caping/Conduit shall be paid as one unit length. | 200.00 | RM |
| 4 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLSH) in existing concealed conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. Note: Two runs of 6.0 Sqmm cable & One run of 6.0 Sqmm cable shall be paid as one unit length. | 2000.00 | RM |
| 5 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 4.0 Sqmm (FRLSH) in existing concealed conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. Note: Two runs of 4.0 Sqmm cable & One run of 4.0 Sqmm cable shall be paid as one unit length. | 400.00 | RM |
20 Days Left