Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4432896 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Comprehensive Maint Of Internal Sub Main Wiring, Mcb Distribution Boards And Meter Control Panels At Zone - I Area Under Ge (a) Jaisalmer |
| Last Date For Submission | 24th Jun, 2026 |
| Opening Date | 26 Jun, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 80000.00 |
| Estimated Cost | 4000000.00 |
| City | Jaisalmer |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. | 125.00 | Each |
| 2 | Taking down the existing unserviceable MCBs/MCCBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. | 596.00 | Each |
| 3 | Taking down the existing old unsv meter panel box description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. | 54.00 | Each |
| 4 | M&L for submain wiring with approved colour code/as per IS with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLSH) in and including medium grade PVC casing & caping/Conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. Note: Three runs of 6.0 sqmm cable & One run of PVC casing & caping/Conduit shall be paid as one unit length. | 900.00 | RM |
| 5 | M&L for submain wiring with approved colour code/as per IS with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLSH) in existing concealed conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. Note :- Three runs of 6.0 Sqmm cable shall be paid as one unit length. | 400.00 | RM |
6 Days Left