| Tender ID | 3691975 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Special Repair To Solar Power Plant And Manning Operation And Maint For Solar Power Plant At Air Force Station Jaisalmer |
| Last Date For Submission | 8th Apr, 2026 |
| Opening Date | 09 Apr, 2026 |
| Document Cost | 1000.00 |
|---|---|
| EMD | 217884.00 |
| Estimated Cost | 14288400.00 |
| City | Jaisalmer |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | PHASE -I (SPECIAL REPAIR TO SOLAR POWER PLANT) | ||
| 2 | Repair/ major overhauling of Grid connected/off load type 250 KWp capacity solar PV plant ground mounted after disconnecting of all strings, testing of solar panel for its serviceability and removal of damaged or faulty solar modules from their existing mounting structures in solar power plant as part of the restoration process, testing of AC string, testing of DC strings, connector, connecting links, refixing of serviceable string, and reconnecting and assembling of solar system complete all as directed at site as per conditions prevailing at Air force station Jaisalmer (Rajasthan) maximum tempreture rise upto 50 degree celscius to considered for the following compnents/Sub System and meeting the specification at site as per eixsting 250 KWp SPV plant at Air force Station Jaisalmer complete all as specified and directed by Engg-in-charge. | 2 | Each Job |
| 3 | Note : 1. The contractor shall identified defective panels & carefully dismantle defective panels , ensuring no damage to the adjacent modules, mounting frames, cables, or electrical connections. 2. All electrical connections shall be properly disconnected and insulated to prevent any short circuits or hazards and proper tools and lifting equipment shall be used to safely detach the panels 3. The removed modules shall be stacked safely in a designated storage area as directed by engg-in-charge 4. Major Spare parts as required to make the solar Power plant as listed below shall be measured and paid seperately. 5. All spare parts required to make the solar plant functional except below shall be deemed to be included in unit quoted rates. | ||
| 4 | M&L for replacement of unserviceable solar module panel, 250 Wp, Model Eldora VSP.60.250.03 complete all as per existing and Re-design (to be vetted by Engr-in-charge.), supply, installation, testing and commissioning of Solar PV Modules which having comptable match with existing solar pv plant system :- Each Module consist of min 250 wp, poly- crystalline silicon with positive tolerance of 3-5% & no negative tolerance is allowed,with minimum 1100 mm cable length. Module efficincy >17%, fill factor>0.7, module will be free of PID, module connector suitable for MC4/Bizlink and jucntion box with minmimum IP 67 rating. Module NOCT (Nominal operating cell temperature) will be 45 3 C with temperature coefficient of power <0.4%/ C, and will be suitable for operation from -20 C to +60 C ambient temperature. | 40 | Each |
| 5 | Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, etc The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards. PV modules must be tested and approved by one of the IEC authorized test centers.Module Warranty The manufacturer should provide warranty the Solar Module(s) to be free from the defects and/or failures specified below for a period not less than twenty five (25) years from the date of commissioning.All photovoltaic modules should carry a linear performance warranty from second year. |