| Tender ID | 4100137 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Provn Of Tolilet Block With Bathroom Facilities Near Building. No T-170 And Special Repair To Building No P-112 (qtr No 29 To 36) Jco Md Accn At Dbn Vihar Under Age B/r-ii Of Ge (e) Jrc |
| Last Date For Submission | 22nd May, 2026 |
| Opening Date | 25 May, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 95920.00 |
| Estimated Cost | 4796000.00 |
| City | Jalandhar |
|---|---|
| State | Punjab |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Demolition of Concrete any description and any position and pavings n.exc 15cm thickness (below or above ground level) all as specified and as directed. | 9.00 | Cum |
| 2 | Demolition of stone slabs and tiles of any description or thickness in floor aprons etc laid bedded and pointed in any mortor complete all as specified. | 69.50 | 10 Sqm |
| 3 | M&L for 75mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection and path finishing the surface even and smooth without using extra cement all as specified and as directed. | 120.00 | Sqm |
| 4 | M&L for 50mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection and path finishing the surface even and smooth without using extra cement all as specified and as directed. | 16.50 | Sqm |
| 5 | M&L for water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:- (i) Application of two components acrylic modified cementious coating;- (aa)The Surface to be applied shall be completely dry and free from containments such as dirt, dust, oil surface treatments and old coatings. Concrete substances must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coating and achieve a gripping profile that is clean, dry and free from laitance and dry other form of surface contamination. The installation instructions in manufacturer's published literature should be strictly complied with including but not limited to the following:-(bb) Chipping out any visible cracks in V-groove pattern as applicable. Special attention on the part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr. Fixit 302 SBR latex/perma lates SBR/FOSROC Nitbond SBR latex/Asian paint latex SBR as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacume pressure if required. (cc) Dampen all surfaces immediately ahed of application of Acrylic modified cementitious coating of SIKA top seal-107/Brush bond FOSROC/Dr Fixit/STP/CICO. (dd) Whilst the surface is still damp from saturation apply one coat of Acrylic modified cementitious coating of SIKA top seal-107/Brush bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturers instructions. | 50.00 | Sqm |