Tendering Authority: Water Supply And Sanitation Department
Tender ID4896751
Organisation NameWater Supply And Sanitation Department
Tender BriefCorrigendum : Replacement Of Outlived 26 No Air Conditioner In Various Court Room At Judicial Court Complex Phillaur
Last Date For Submission27th Jul, 2026
Opening Date27 Jul, 2026
Cost
Document Cost1000.00
EMD31882.00
Estimated Cost1593519.00
Location
CityJalandhar
StatePunjab

Register to see full details

BOQ Items
#ItemQtyUnits
1Providing & installing & Erection split inverter type wall mounted air conditioner capacity 2.0 tonne 3 star rating for 230 volts single phase supply with nature friendly refrigerant R32 rated cooling capacity >5 condenser coil make copper, installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects.13Each
2Providing & installing & Erection split inverter type wall mounted air conditioner capacity 1.5 tonne 3 star rating for 230 volts single phase supply with nature friendly refrigerant R32 rated cooling capacity >5 condenser coil make copper, installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects.13Each
3AUTOMATIC VOLTAGE STABLIZER:
4Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-
5Automatic Voltage Stablizer 5 KVA26Each