Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4782533
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Cwek/t-34/864 Ews/2026-27 Provn Of Hot Water Generator For Certain Bldgs At Bb Cantt, Srinagar In The Aor Of Age E/m And Age B/r-iii Under Ge 864 Ews
Last Date For Submission3rd Aug, 2026
Opening Date11 Aug, 2026
Cost
Document Cost1000.00
EMD155900.00
Estimated Cost8725000.00
Location
CityJammu
StateJammu and Kashmir

Register to see full details

BOQ Items
#ItemQtyUnits
1OIL FIRED BOILER :- Supply, installation, testing & commissioning of oil fired boiler type hot water generator system using operating media as fuel Kerosene/HSD oil based system of rated capacity 2,00,000 Kcal/hrs. at MSL unit complete set and with having three pass reverse flame combustion chamber, fire tubes and equipment like automatic type monoblock burner assembly set with suitable using and smooth running/operating for oil fired boiler type hot water generator system of rated of capacity 2,00,000 Kcal/hrs. at MSL unit system along with having heating tubes, temperature controller, sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, thermostat, pressure gauges/temperature gauge and air release valve for inlet & outlet pipe line connection attachment system. The hot water generator system shall properly maintain of hot water inlet temperature, out let temperature from 55 degree to 65 degree centigrade/Celsius The generator combustion chamber shall be insulated with fiber glass/ elastomeric insulation with aluminium foil insulation wool housed in the powered coated/prepainted sheet metal casing/body complete all as specified and directed. Make: Reillo/Thermax/Ecoflame/ Western / Rapid thermo Note- (a) If any miscellaneous ,minor specification of items and other quantity of minor items which are/is not mentioned / covered under this item/schedule but required for the Hot water generator system for installation / commissioning purposes it shall be provided by the contractor as per OEM specifications/ recommendations and the cost of the same shall be deemed inclusive in the quoted rate. (b) Before installation of hot water generator unit , the contractor have to produce the OEM manufacturer test certificate and purchase voucher before to GE / Engineer In Charge for their further direction and necessary action. (c) The quoted rate shall be deemed inclusion of provision of necessary PCC/RCC/MS base frame foundation work for installation of chimney, pump motor, boiler, tank, panel etc. and other equipments as per specified by OEM.2.00Each
2All as per serial item No. 1 here-in-before, but Oil Fired Boiler type hot water generator system of rated capacity 150000Kcal/hrs at MSL.2.00Each
3HOT WATER CIRCULATION CENTRIFUGAL PUMPS:- Supply, installation, testing & commissioning and including designing of monoblock centrifugal pump with motor system and with having operating electrically driven type of required rating capacity and with having water lifting head at 15 to 20 Mtr and discharge flow rate of capacity 250 LPM and including pump motor having mechanical seal bearing for holding temperature upto 90 C of hot water and suitable used for hot water circulation system complete alongwith connected fixing accessories and also providing and making with inter connecting ring man piping lines system for using of both plants alternative attachment system to each other and also providing foundation work and duly fixing it upon the MS/PCC/RCC base frame framing work all as specified and directed. (01 No working and 01 No standby for each plant). Make:Wilo,/Armstrong/Grundfos/ Kirloskar.4.00Each
4All as per serial item No. 3 here-in-before, but hot water circulation monoblock centrifugal pump of rated of capacity 180 LPM complete all as specified and directed. (01 No working and 01 No standby for each plant)4.00Each
5HOT WATER RE CIRCULATION PUMPS:- Supply, installation, testing & commissioning and including designing of thermostatic return circulation/ monoblock centrifugal pump with motor system and with having operating electrically driven type of required rating capacity and with having water lifting head at 6 to 12 Mtr and discharge flow rate of capacity from 40 LPM to 60 LPM and including pump motor having mechanical seal bearing for holding temperature upto 90 C of hot water and suitable used for hot water re circulation system complete alongwith connected fixing accessories and also providing and making with inter connecting ring man piping lines system for using of both alternative attachment system to each other and also providing foundation work and duly fixing it upon the MS/PCC/RCC base frame framing work complete all as specified and directed. Make:Wilo,/Armstrong/Grundfos /Crompton Greves)4.00Each
3rd Aug, 2026

6 Days Left

WhatsApp