Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4461313 |
|---|---|
| Organisation Name | Public Works Department |
| Tender Brief | Design, Supply, Installation, Testing, Commissioning Of Hvac System At Teaching Hospital, Government Medical College Doda |
| Last Date For Submission | 20th Jun, 2026 |
| Opening Date | 22 Jun, 2026 |
| Document Cost | 3000.00 |
|---|---|
| EMD | 996000.00 |
| Estimated Cost | 49794781.00 |
| City | Jammu |
|---|---|
| State | Jammu and Kashmir |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | AIR DISTRIBUTION (FOR AIRCONDITIONING) GSS DUCTING | ||
| 2 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as specifications of following sheet thickness complete as required. In special situations in health care facility (e.g., operating rooms, delivery rooms, catheterization laboratories, angiography rooms ICU/ CCU, HEPA-filtered rooms for immune-suppressed patients) Iincluding the specifications given below the direction of air movement needs to be controlled. The air is introduced from ceiling registers on the perimeter and is returned or exhausted through registers located at least 6 inches above the floor. This arrangement provides a downward movement of clean air through the breathing and working zones to the contaminated floor area for exhaust. | ||
| 3 | 0.63 MM (24 gauge) Galvanized Sheet Steel Ducting | 1400 | Sqm. |
| 4 | 0.80 MM (22 gauge) Galvanized Sheet Steel Ducting | 400 | Sqm. |
| 5 | Supply, installation, balancing and commissioning of fabricated at site fabricated Aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. and specifications of following sheet thickness complete as required. In special situations in health care facility (e.g., operating rooms, delivery rooms, catheterization laboratories, angiography rooms ICU/ CCU, HEPA-filtered rooms for immune-suppressed patients) Iincluding the specifications given below the direction of air movement needs to be controlled. The air is introduced from ceiling registers on the perimeter and is returned or exhausted through registers located at least 6 inches above the floor. This arrangement provides a downward movement of clean air through the breathing and working zones to the contaminated floor area for exhaust. |
18 Days Left