Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4613961 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Provision Of False Ceiling At Building No P390 And Addn Altn To Toilet At Snco Mess Building No P1389 And Improvement To Electrical Infra At Building No P390 And Provision Of Bitumen Mastic Flooring At Lpg Godown At Ge Af No 2 Jodhpur |
| Last Date For Submission | 6th Jul, 2026 |
| Opening Date | 08 Jul, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 33181.00 |
| Estimated Cost | 1658127.00 |
| City | Jodhpur |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (roof padding, flooring above ground floors) including roof treatment and removing from site all as specified and directed. | 1.75 | Cum |
| 2 | M&L PCC 1:3:6 type C-0 (using 12.5 mm graded stone aggregate) as in roof padding (average thikness 50mm thick) complete as directed by Engineer-in-Charge | 1.00 | Cum |
| 3 | M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. NOTE : Water proofing compound shall be measured and paid for separately as Supply only . | 45.00 | Sqm |
| 4 | M & L for prepration of surface and providing Waterproofing membrane moisture cured, Polyurethane elastomeric liquid membrane waterproofing coating cold applied with brush/roller, with an elongation of >500% and tensile strength of 2 MPa as per ASTM D 412, 90 % Solid Content, shore A Hardness of min 50 as per ASTM D 2240, The system includes final base preparation as per note given below, PU primer application at 8Sqm/L and applying PU chemical in two coats at 1.8 kg per Sqm providing 1.5 mm DFT, complete as per Manufacturer specifications, Waterproofing membrane to be terminated on parapet wall in a V groove of size 25 mm x 25 mm atleast 300 mm above FFL which should be sealed with Polymer Mortar complete all as specified and directed for work in building/structure of any height, Completed as per manufacturer instruction. Note: Surface Preparation: (i) The surface to be treated should be sound and free from all types of dirt, dust and debris. Clean surface by brushing, scraping or chipping to eliminate all defective materials and foreign matter. Proper surface preparation needs dry mechanical grinding to expose base Substrate. Making of angle fillets(75mmx75mm all around the periphery of the wall with polymer modified mortar using SBR Latex (ii) All construction joints and cracks > 1mm shall be treated by cutting V groove and filling with polymer modified SBR Latex and reinforced with geotextile membrane dipped in PU liquid Membrane before the 1st coat application. (Non Accessible roofs) | 45.00 | Sqm |
| 5 | Supply only integral water proofing compound ISI marked. | 11.35 | Kg |
11 Days Left