| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Taking down old unserviceable/worn out sub main wiring/service wire of any type and size complete all as specified. | 700.00 | RM |
| 2 | M & L in replacement for Sub main wiring complete with single core 1.5sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 1.5 sqmm in and including Steel conduit on surface and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor(P+N+E) and one run of steel conduit shall be measured as one unit length.) | 150.00 | RM |
| 3 | M & L in replacement for Sub main wiring complete with single core 1.5sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 1.5 sqmm in existing steel/PVC conduit on surface/concealed and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor(P+N+E) and one run of conduit shall be measured as one unit length.) | 150.00 | RM |
| 4 | M & L in replacement for Sub main wiring complete with single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 2.5 sqmm in and including Steel conduit on surface and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm(P+N+E) conductor and one run of steel conduit shall be measured as one unit length.) | 90.00 | RM |
| 5 | M & L in replacement for Sub main wiring complete with single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 2.5 sqmm in existing steel/PVC conduit on surface/concealed and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of conduit shall be measured as one unit length.) | 90.00 | RM |