Tender BriefSpecial Repair To Building No. P-207/01 To 12 (or Md Accn) At Shikargarh And Roof Treatment Of Building No. P-236 Of Certain Unit At Army Area Jodhpur Under Ge (army) No. 02
Last Date For Submission27th Jun, 2026
Opening Date29 Jun, 2026
Cost
Document Cost1000.00
EMD132250.00
Estimated Cost7150000.00
Location
CityJodhpur
StateRajasthan

Register to see full details

BOQ Items
#ItemQtyUnits
1Demolition of cement concrete of any description and in any position not otherwise specifically provided for (such as copings, bands of any type, roof padding, kerbs, sunken etc; overall thickness and removing the dust debris etc to a distance not exc 250 meter from site and disposing the same complete all as specified and as directed by Engr in Charge.64.00Cum
2M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates as over roof for making good depression/ undulation to make the existing roof surfaces as filling in depression of roof slab/ floor padding/ roof kerbs rounded or chamfered on edges etc complete all as specified and as directed by Engr in Charge.57.00Cum
3M&L providing and applying roof treatment as following stage:- (i) Apply 1st coat of PU coating ( Shaliurethane LHM @ 650gm/Sqm or equivalent by brush/roller/spray. Spread non-woven geo-textile or glass fiber tissue of 45 GDM with overlaps of 50 mm in both directions when the surface is still tacky, this is optional,to be assessed as per site requirements to achieve higher mechanical properties. (ii) Allow 1st coat to dry for 10-12 Hrs. (iii) (Apply 2nd coat of PU membrane (ShaliUrethane LHM @ 650gm/sqm or equivalent)as per manufacturs instructions. Extend waterproofing treatment up to 200 mm and terminate into groov on the parapet wall. (iv) Protect the applied liquid membrane by sprinkling sand @ 200gm/Sqm over the final coating when the surface is still tacky to facilitate plastering, and including 25 mm thick plastering in CM 1:3 with admixture and water proofing compound. Note No-1:- treatment shall be done though authorised representative of manufacture's instructions.complete all as specified and as directed by Engr in Charge. 390.00Sqm
4M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates as in roof kerbs rounded or chamfered on edges etc complete all as specified and as directed by Engr in Charge.1.50Cum
5M&L for plain cement concrete 1:3:6 type B1, using 20mm graded stone aggregates as in coping to parapet walls including necessary form work complete all as specified and as directed by Engr in Charge.7.00Cum