| Tender ID | 4779075 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair/ Maintenance To Window/split Ac, Refrigerator, Deep Freezer, Humidifier, Voltages Stabilizer Etc. At Afh Under Ge (af) Jorhat |
| Last Date For Submission | 27th Jul, 2026 |
| Opening Date | 29 Jul, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 60000.00 |
| Estimated Cost | 0.00 |
| City | Jorhat |
|---|---|
| State | Assam |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | M&L for servicing of 1.5/2.0/3.0 TR capacity window/split type AC after disconnecting from electric supply, opening suction and dicharge pipes of outer unit and removing scratch, dust with iron brush, cleaning condensor unit, compressor, cooling coil/cleaning of fan blade/cleaning of filter of inner unit etc, including checking thermostate, starting capacitior, running capacitor, etc. with jet spray water and air blower at the site and reinstall the same at the same place including Re-filling/re-charging of refregerent Gas as required complete all as specified and as directed. | 180.00 | Each Job |
| 2 | Taking down/up defective AC (Window/Split type) 1.5 TR capacity, transportation from MES Store Yard/Site to Workshop and back including re-fixing /re-installing after taking out defective/burnt rotary type compressor sealed unit and providing new compressor of same capacity from Authorised Dealer including flushing of condenser after charging with required quantity of appropriate Refrigerant Gas including re-connection of Electric Connections, functioning AC complete in all respect and testing complete all as specified and as directed | 13.00 | Each Job |
| 3 | Taking down/up defective AC (Window/Split type) 1.5 TR capacity, transportation from MES Store Yard/Site to Workshop and back including re-fixing/re-installing after taking out defective/burnt reciprocating type compressor sealed unit and providing new Compressor of same capacity from Authorised Dealer including flushing of condenser after charging with required quantity of appropriate Refrigerant Gas including re-connection of Electric connections, functioning AC complete in all respect and testing complete all as specified and as directed. | 8.00 | Each Job |
| 4 | All as per Serial item No. 2 here-in-before including makes but AC (Window/Split Type) 2.0 TR Capacity. | 9.00 | Each Job |
| 5 | All as per Serial item No. 3 here-in-before but AC (Window/Split Type) 2.0 TR capacity Note (for Serial item No. 1 to 5 above) : Re-filling and Refreigerant Gas shall be measured and paid separately as required to fill as per requirement/ manufacturer instruction excluding measurement of gas filled by OEM. | 5.00 | Each Job |