| Tender ID | 4256819 |
|---|---|
| Organisation Name | Airports Authority Of India |
| Tender Brief | Corrigendum : Annual Repairs, Servicing And Allied Electrical Works At Kadapa Airport |
| Last Date For Submission | 9th Jun, 2026 |
| Opening Date | 10 Jun, 2026 |
| Document Cost | 1180.00 |
|---|---|
| EMD | 48076.00 |
| Estimated Cost | 1602526.00 |
| City | Kadapa |
|---|---|
| State | Andhra Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | SH: I Calibration of following relays of Crompton Greaves make HT Switching panel with three VCB's(01-I/C , 02-O/G), using secondary injection kit including adjustment of plug settings, transportation of test equipment to site for performinmg the tests and submitting test reports etc as required: 1. Over Current + Earth Fault relays- (Make: Genesis EASUN REYROLLE ,Model -MIT113) per VCB 2. Auxiliary realy for transformer fault alarm (one per each transformer T/F-1 & 2) - Buchholz , Traformer Winding Temperature, Transforemer Oil temperature ( Make : Easun Reyrolle, Model: B33X3) 3. Auxilliary relay for tranformer fault trip (one per each transformer T/F-1 & 2) - Buchholz , Traformer Winding Temperature, Transforemer Oil temperature ( Make : Easun Reyrolle, Model: B33X3) . | 1.00 | Job |
| 2 | Inspection, servicing and testing of 800A C&S make Air circuit breakers including carrying out preventive maintenance asper OEM recommendations and submission of test reports etc. as required (Excluding cost of spares) | 3.00 | Job |
| 3 | Carrying out the BDV test & Acidity test of the transformer oil,through a NABL accredited lab/Govt. approved lab or through portable test facility at site and submission of the test reports to AAI. The cost shall include all expenses towrads collection of samples as per the requirements of the testing lab/ facility, transporting the samples to the test lab ( as applicable), to and fro transportation and engaging skilled person to conduct the tets at site, in case of using portable test failcity for site testing and any other incidental charges associated with the performing of these test etc. in complete etc. as required. | 4.00 | Job |
| 4 | Filtration of insulation oil of 400 KVA, 11 / 0.415 KV transformers by stream line and hot oil circulation for three cycles or more till achieving required value including certification, transportation ( to & fro) of machineries etc.complete as required (400 KVA transformer Oil tank capacity - 415 ltr). | 2.00 | Job |
| 5 | Calibration of the following measuring instruments possessed by AAI from any NABL accredited lab/Govt. approved lab and submission of the calibration certificates to AAI |