Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Nuclear Power Corporation Of India Limited
Tender ID3471490
Organisation NameNuclear Power Corporation Of India Limited
Tender BriefCorrigendum : Acoustic, Interior, Furniture, Audio Visual And General Lighting And Fixtures Works For Quality Assurance Qa Complex Building At Kaiga-5 And 6.
Last Date For Submission1st Apr, 2026
Opening Date04 Apr, 2026
Cost
Document Cost0.00
EMD1064831.00
Estimated Cost53241544.00
Location
CityKaiga
StateKarnataka

Register to see full details

BOQ Items
#ItemQtyUnits
1PART-A : ACOUSTIC WORKS Supply and fixing of suspended acoustical GI metal Hanging Baffles based of wooden finished texture having NRC Value up-to 0.70 NRC. The baffle shall be of sizes 50mm thick and 100mm height. The baffles with end caps will be installed using all hardware s and accessories including runners, suspended wires, etc. The interspacing distance between the Baffles will be 100mm. The Baffles to be suspended individually using the runners tied by 6mm Threaded rod, including all other hardware s and accessories, etc., including fixing & removing Staging /platform / ladder wherever required, collecting & disposing the generated waste & construction waste etc, away from work premises & cleaning the work area etc, complete all as per standard & manufacturer s specification and as directed by Engineer-in-charge at all locations and at all lifts & height. Note: Product shall be of make Indosonic/Hunter Douglas/Durlum or approved make.850.00sqft
2PART-A : ACOUSTIC WORKS Providing, placing and fixing 12.5mm Moisture Resistant Gypsum based false ceiling at all height, including providing and fixing of frame work made of special sections, power pressed from MS. sheets and galvanized with zinc coating of 120 gms/sqm (both sides inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20mm and 30 mm long including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up-to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, including fixing & removing Staging /platform / ladder wherever required, collecting & disposing the generated waste & construction waste etc, away from work premises & cleaning the work area etc, complete all as per standard & manufacturer s specification and as directed by Engineer-in-charge at all locations and at all lifts & height. Note: Product shall be of make India Gypsum / Gyproc/ Knauf or approved make. 2150.00sqft
3PART-A : ACOUSTIC WORKS Providing & Fixing of Aluminium metal tiles in horizontal level suspended ceiling comprising of Lay-in 6mm to 8mm Perforated metal ceiling consisting of 600x600mm (Nominal Size) Lay-in tiles suitable for architectural finishes in 0.7 mm thickness in wooden finished colour powder coating (ranging from 60-80 microns) with Square Regular edge. The Back side of the tile will have 1mm acoustic Freudenberg fleece to achieve NRC up to 0.7 as per ASTM C-423 and Fire Performance of Class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. The installation will be done on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main T . The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size 15x15X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications including fixing & removing Staging /platform / ladder wherever required, collecting & disposing the generated waste & construction waste etc, away from work premises & cleaning the work area etc, complete all as per standard & manufacturer s specification and as directed by Engineer-in-charge at all locations and at all lifts & height. Note: Product shall be of make Indosonic/Armstrong/Hunter Douglas or approved make. 2000.00sqft
4PART-A : ACOUSTIC WORKS Providing & Fixing of 4' X 2' aluminium based glossy wooden finished metal tiles of thickness 0.7mm. The installation will be done on the frame work shall consist of G.I. ' T ' Sections of 25 micron hot dipped galvanised iron section of 0.40mm thick on Silhouette profile, rotary stitched double webbed wooden finish with 6mm reveal profile (white/black) compromising of Main runners 15x42x3000mm length, Cross runners of 15x42x1200mm & 15x42x600mm size to form grid module of size 1200x600mm. Galvanised iron perimeter wall angle of size 15x19x0.4mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm C/C and 40mm long dry wall SS screws. The work shall be carried out as per specifications including fixing & removing Staging /platform / ladder wherever required, collecting & disposing the generated waste & construction waste etc, away from work premises & cleaning the work area etc, complete all as per standard & manufacturer s specification and as directed by Engineer-in-charge at all locations and at all lifts & height. Note: Product shall be of make Indosonic/Armstrong/Hunter Douglas or approved make. 800.00sqft
5PART-A : ACOUSTIC WORKS Providing, placing & Fixing of SS 304 grade plain metal tiles in horizontal level suspended ceiling comprising of Lay-in metal tiles consisting of 600x600mm (Nominal Size) Lay-in tiles suitable for architectural finishes in 0.5/0.7 mm thickness with Square Regular edge. The installation will be done on an interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main T . The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be of SS cladded Layer, for all heights. The work shall be carried out as per specifications (if any )s and as per directed by Engineer-in-charge, including fixing & removing Staging /platform / ladder wherever required, collecting & disposing the generated waste & construction waste etc, away from work premises & cleaning the work area etc, complete all as per standard & manufacturer s specification and as directed by Engineer-in-charge at all locations and at all lifts & height. Note: Product shall be of make Armstrong/Anutone /Indosonic or approved make 350.00sqft
1st Apr, 2026