#ItemQtyUnits
1Providing and installing Long Guage Extensometer Multiplebore hole Extenssometer For Concrete Spillway. Specification Measurement Range: 0 300 mm Accuracy: 0.1% F.S. Resolution: 0.01 mm Protection: IP68 Cable Requirement: Shielded, UV resistant, armoured, 4-core Installation: Installed in drilled borehole with anchors at specified depths Calibration: Factory calibration with traceable certificate Acceptance Tests: Calibration certificate, insulation test, field baseline reading8.000No.
2Providing and installing Tiltmeter For Concrete Spillway. Specification Measurement Range: 0 300 mm Accuracy: 0.1% F.S. Resolution: 0.01 mm Protection: IP68 Cable Requirement: Shielded, UV resistant, armoured, 4-core Installation: Installed in drilled borehole with anchors at specified depths Calibration: Factory calibration with traceable certificate Acceptance Tests: Calibration certificate, insulation test, field baseline reading8.000No.
3Providing and installing Temperature Stress For Concrete Spillway. Specification Measurement Range: 0 300 mm Accuracy: 0.1% F.S. Resolution: 0.01 mm Protection: IP68 Cable Requirement: Shielded, UV resistant, armoured, 4-core Installation: Installed in drilled borehole with anchors at specified depths Calibration: Factory calibration with traceable certificate Acceptance Tests: Calibration certificate, insulation test, field baseline reading65.000No.
4Providing and installing Laser Plumb bob For Concrete Spillway. Specification Measurement Range: 0 300 mm Accuracy: 0.1% F.S. Resolution: 0.01 mm Protection: IP68 Cable Requirement: Shielded, UV resistant, armoured, 4-core Installation: Installed in drilled borehole with anchors at specified depths Calibration: Factory calibration with traceable certificate Acceptance Tests: Calibration certificate, insulation test, field baseline reading1.000No.
5Providing and installing Pore pressure Transducers For Earthen Dam. Specification Measurement Range: 0 300 mm Accuracy: 0.1% F.S. Resolution: 0.01 mm Protection: IP68 Cable Requirement: Shielded, UV resistant, armoured, 4-core Installation: Installed in drilled borehole with anchors at specified depths Calibration: Factory calibration with traceable certificate Acceptance Tests: Calibration certificate, insulation test, field baseline reading25.000No.