Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: NHDC Limited
Tender ID3639590
Organisation NameNHDC Limited
Tender BriefCorrigendum : Construction Of Shed For Hydro-mechanical (hm) Works At Gallery Site On Right Bank Of Indira Sagar Dam At Indira Sagar Power Station, Narmada Nagar, Distt.-khandwa (m.p.).
Last Date For Submission16th Apr, 2026
Opening Date20 Apr, 2026
Cost
Document Cost590.00
EMD66000.00
Estimated Cost3281137.00
Location
CityKhandwa
StateMadhya Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil42.78m3
2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 40mm nominal size graded stone aggregate. M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate )2.05m3
3Providing and laying in position machine batched, machine mixed cement concrete (BMC) of M-25 grade for reinforced cement concrete work using cement content as per approved mix design including use of admixtures in recommended proportions as per IS 9103 to accelerate/retard setting, improve workability of concrete without impairing strength and durability as per direction of Engineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 330 kg/cum) and no extra payment for extra cement used as per mix design. All works up to plinth level.13.02m3
4Providing and laying in position machine batched, machine mixed cement concrete (BMC) of M-25 grade for reinforced cement concrete work using cement content as per approved mix design including use of admixtures in recommended proportions as per IS 9103 to accelerate/retard setting, improve workability of concrete without impairing strength and durability as per direction of Engineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 330 kg/cum) and no extra payment for extra cement used as per mix design. Above plinth up to floor 557.26m3
5Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size).6.70m2
16th Apr, 2026

6 Days Left

WhatsApp