| Tender ID | 4271927 |
|---|---|
| Organisation Name | Airports Authority Of India |
| Tender Brief | Provision Of Ils At Kishangarh Airport Ajmer. Sh-electrical Works Related To Aerosol Based Fire Extinguishing System And Addressable Fire Alarm And Detection System. |
| Last Date For Submission | 3rd Jun, 2026 |
| Opening Date | 04 Jun, 2026 |
| Document Cost | 94060.00 |
|---|---|
| EMD | 1180.00 |
| Estimated Cost | 3135334.00 |
| City | Kishangarh |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Design, Manufacturing and Supply of Fixed Aerosol based Fire Extinguishing system for Equipment Room of (4040(L) x5000(W)x3500(H) mm) having No false ceiling and No False flooring including following major system equipment UL/EN/GOST R53284 listed and in compliance to NFPA 2010/ISO, with upto date amendments and with required fittings and accessories as per technical specification. (A) Suitable nos Electrically operated/actuated Condensed Aerosol generator of suitable capacity of aerosol generating solid compound based on UL/EN/GOST R53284/ISO15779 approved design concentration, Powder-coated MS Body,Stainless Steel Mounting Brackets for Extinguishing generators, applicable for A, B & C class of Fire with Volumetric Design Consideration, Zero Ozone Depletion potential & Zero Global Warming Potential, Negligible Atmospheric LifeTime. (B) Sequential Activator suitable for operate aerosol generators with LED fault indicator. (C) Simulation lamps for testing the signals to the generators. (D) Conventional Agent Release Panel, 4-Zone, LCD display listed to UL/EN and complies with NFPA-72 including battery backup,provision of testing and reseting, gas release indication alarms and system wiring meeting all system requirements etc. complete as required. (E) Conventional type multi criteria (Smoke+heat) detectors UL/EN listed. (F) Manual gas release and gas abort station having manual break glass push button UL/EN listed. (G) Outdoor Flameproof Hooter cum strobe UL/EN listed. (H) Alarm LED signages (DO NOT ENTER & EVACUATE IMMEDIATELY) and Instruction chart. (I) Any other equipments required as per site requirement complete as required. ( Except supply and laying of fire survival cable) (J) Design of complete Fixed Aerosol Fire Extinguishing system shall be duly vetted by the OEM or his authorized dealer. (K) Installation Testing and Commissioning of complete system as per site requirement. | 2 | Job |
| 2 | Design, manufacturing and SITC of Fixed Aerosol based Fire Extinguishing system for Battery Room(3720(L) x 5000(W) x 3500(H) mm) having No false ceiling and No False flooring including following major system equipment UL/EN/GOST R53284 listed and in compliance to NFPA 2010/ISO, with upto date amendments and with required fittings and accessories as per technical specification. (A) Suitable nos Electrically operated/actuated Condensed Aerosol generator of suitable capacity of aerosol generating solid compound based on UL/EN/GOST R53284/ISO15779 approved design concentration, Powder-coated MS Body,Stainless Steel Mounting Brackets for Extinguishing generators, applicable for A, B & C class of Fire with Volumetric Design Consideration, Zero Ozone Depletion potential & Zero Global Warming Potential, Negligible Atmospheric LifeTime. (B) Sequential Activator suitable for upto 3 generators with LED fault indicator. (C) Simulation lamps for testing the signals to the generators. (D) Conventional Agent Release Panel, 4-Zone, LCD display listed to UL/EN and complies with NFPA-72 including battery backup,provision of testing and reseting, gas release indication alarms and system wiring meeting all system requirements etc. complete as required. (E) Conventional type multi criteria (Smoke+heat) detectors UL/EN listed. (F) Manual gas release and gas abort station having manual break glass push button UL/EN listed. (G) Outdoor Flameproof Hooter cum strobe UL/EN listed. (H) Alarm LED signages (DO NOT ENTER & EVACUATE IMMEDIATELY) and Instruction chart. (I) Any other equipments required as per site requirement complete as required. ( Except supply and laying of fire survival cable) (J) Design of complete Fixed Aerosol Fire Extinguishing system shall be duly vetted by the OEM or his authorized dealer. (K) Installation Testing and Commissioning of complete system as per site requirement. | 2 | Job |
| 3 | Supply, installation, Testing & commissioning of IP based Addressable type Fire Alarm control panel of minimum 2 loops (each Loop card having capacity to accommodate minimum 20 detectors and 20 modules) with the following facilities like 80 character display unit, power supply unit, built in battery charger, including 24 Volts sealed maintenance free lead acid batteries for 02 hours backup, suitable for Auto dialer facility, web server PCB for IP connectivity etc. complete as required. | 2 | Job |
| 4 | SITC of 02 channel wireless auto dialer (GSM based), (Voice and SMS) having facitlity of storing voice message & min. 10 contact numbers, work with all types of GSM network, 1 levels of password protected with all necessary accessories including SIM ( as per site requirement) with 1 year recharge, connections beween fire alarm panel etc, complete as required. | 2 | Job |
| 5 | Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector (Smoke + heat) ( Base Included) with inbuilt fault isolator isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed on ceiling etc. complete as required. | 16 | Each |