Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4644110 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair/maintenance Of Chloronome Plants, Pump Sets, And Control Pannels, Solar Water Heater Etc At Naval Base Area Including All Units, Garuda And Kataribagh Area At Naval Base, Kochi |
| Last Date For Submission | 14th Jul, 2026 |
| Opening Date | 16 Jul, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 89940.00 |
| Estimated Cost | 0.00 |
| City | Kochi |
|---|---|
| State | Kerala |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Maintenance of liquid chlorinators installed at Naval Base area including repair /renewal /replacement of defective parts and servicing ,cleaning and checking by providing specialist tradesman to ensure 100 % serviceability of the liquid chlorinator plants "round the clock including Saturday /Sunday /Holiday " and to obtain required dosage in the entire Naval base and Kataribagh area as per satisfaction of Engineer-in -charge .The chlorine testing Kit should be provided at each installation in responsibility of the contractor for testing the water any time complete all as specified and as directed .The spares which ever be required for making serviceability of the plants shall be measured and paid separately under relevant item of this schedule. | 11.00 | Per Month |
| 2 | LIQUID CHLORINATOR PLANTS :- (a) Main Pump House at Kataribagh - 02 Nos (b) South Jetty Pump House - 01 Nos (c) Atithi Pump House - 01 Nos (d) 224 Men Pump House - 01 Nos (e) 300 Men Pump House -01 Nos (f) INHS Sanjivani Pump House -01 Nos (g) 29 CPOs Pump House - 01 Nos (h) 32 CPOs Pump House -01 Nos (k) SNC 'O' Mess Pump House - 01 Nos (l) 60 'G' Pump House -01 Nos (m) 96 'G' Pump House -01 Nos (n) 900 Men Pump House - 01 Nos (o) HQ Venduruthy Pump House - 01 Nos | ||
| 3 | NOTE FOR DAILY ROUTINE MAINTENANCE TASK :- (a) Checking of all parts of the plants for its functional properly . (b) Calibrating and dozing the plant to obtain variable dosage up to 0.50 PPM (c) Testing of chlorinated supply water for correct dosage minimum up to 2 PPM or as required in Main pumping installation at KB to maintained 0.5 PPM at users end. (d) Records of testing of dosage with time shall be maintained properly . (e) Plant serviceability /Maintenance records shall be maintained properly. (f) Tradesman employed shall be have minimum two years experience for operating the pump set from any prestigious firm /Govt or semi Govt organisation. (g) Spares repair/replacement shall be measured and paid separately . (h) The rate of consumable minor spares shall deemed to be included in the unit rate quoted by the tenderer . | ||
| 4 | Material and labour for disconnecting of unserviceable dozing granular motor agitator of capacity 0.5 HP from mixture dozing tank complete opening the unserviceable motor agitator at site to located the fault and than transporting to the local work shop . Opening and cutting/removing burnt out winding and rewinding the motor with as per existing suitable gauge super enamelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating up to varnish fully dry properly. Re-assembling the motor agitator and testing at workshop after complete repairs work and transported back and installed at site as per existing position and testing compete with out any leakage complete all as specified and as directed | 12.00 | Each |
| 5 | Supply only dozing granular motor agitator of capacity 0.5 HP complete all as specified and as directed | 5.00 | Each |
6 Days Left