Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4351956 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair/maintenance Of Distribution Transformers And Protective Relays And Connected Works At Ins Dronacharya And Sma Rameshwaram Under Ge Fort Kochi. |
| Last Date For Submission | 18th Jun, 2026 |
| Opening Date | 22 Jun, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 29980.00 |
| Estimated Cost | 1499000.00 |
| City | Kochi |
|---|---|
| State | Kerala |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | GENERAL NOTE:- The contractor shall visit the site before quoting the tender and get acquaint himself regarding the make/ type of transformer etc, inorder to get a clear knowledge of site and quote accordingly. Nothing extra shall be admissible on this account please. | ||
| 2 | Material and Labour for repair of Transformers 11 KV/433 Volts on site of any make installed at various location of Sub Stations, including disconnecting the HT/LT Cables, earth strips etc. from the transformer, draining the complete oil for removing sludge from the tank refilling and removing the top cover, conservator, explosion vent,etc, for detecting the faults and repairing by welding/bracing. Replacing all the gaskets & neoprene washers for leakage arresting. Reassembling the transformer and testing etc complete upto 400 KVA capacity complete all as specified and directed by the Engineer-in-charge. Note :- Supply only new transformer oil and oil filtration shall be measured and paid under the schedule of relevant items. | 1.00 | Each Job |
| 3 | Material and Labour for repair of Transformers 11 KV/433 Volts on site of any make installed at various location of Sub Stations, including disconnecting the HT/LT Cables, earth strips etc. from the transformer, draining the complete oil for removing sludge from the tank refilling and removing the top cover, conservator, explosion vent, etc, for detecting the faults and repairing by welding. Replacing all the gaskets & neoprene washers for leakage arresting. Reassembling the transformer and testing etc complete from 500 to 800 KVA capacity complete all as specified and directed by the Engineer-in-charge. Note :- Supply only new transformer oil and oil filtration shall be measured and paid under the schedule of relevant items. | 1.00 | Each Job |
| 4 | Supply and fix in repairs 11000V Bushing as per site requirements with superior quality brass rods complete with and including necessary Rubber `O' ring/oil seals and gaskets for distribution transformers of capacity up to 800 KVA complete all as specified and directed by the Engineer-in-charge. | 3.00 | Each |
| 5 | Supply and fix in repairs 415 V Bushing porcelain with superior quality brass rods complete with and including necessary Rubber `O' ring/oil seals and gaskets for distribution transformers of capacity up to 800 KVA complete all as specified and directed by the Engineer-in-charge. | 3.00 | Each |
6 Days Left