Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID5003056
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Repair And Maint Of Fans, Exhaust Fans And Geyser Including Other Connected Works Of Hasting And Strand Line Area Under Ge (central) Kolkata
Last Date For Submission13th Aug, 2026
Opening Date14 Aug, 2026
Cost
Document Cost500.00
EMD60000.00
Estimated Cost3000000.00
Location
CityKolkata
StateWest Bengal

Register to see full details

BOQ Items
#ItemQtyUnits
1Dis-assembling carefully ceiling fans (any make) of 1200/1400mm, sweep, cutting & removing old copper winding wire and rewinding the same with new super enameled copper wire of suitable size / gauge and providing insulation by varnishing the winding, oiling and greasing, including replacing bearing and gun metal shaft if required including painting the complete fan and reassembling back testing complete:- Note :- (i) Cost of bearing shall be deemed to be included in quoted rates. (ii) Working space if required, will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises. (iii) If wound fan found unserviceable within six month of rewinding, contractor will repair the same without any extra cost. (iv) Cost of machining work in body of ceiling fan by taking out worn out bearing, boring hole to accommodate ball bearing is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying ceiling fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard (vi) Cost of shaft will be paid under appropriate item of schedule450.00Each
2Dis-assembling of exhaust fan of size above 300mm & upt 450mm size/sweep, AC 230 Volts, 50Hz 900/1400 RPM for repair, removing existing burnt winding wire, bearing/bushes, flexible wire, shaft, check nuts, frame and rewinding with super enameled copper winding wire of suitable size gauge to produce required output with and including replacement of bushes, bearings shafts, check nuts, bolts and washers, greasing, varnishing and reassembling back including testing complete. (i) Cost of bushes/bearings/shaft provided shall be deemed to be included in quoted rate. (ii) Working space if required, will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises. (iii) If wound exhaust fan found unserviceable within six month of rewinding, contractor will repair the same without any extra cost. (iv) Cost of machining work in body of exhaust fan by taking out worn out bust, boring hole to accommodate ball bearing is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying exhaust fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard 5.00Each Job
3Dis-assembling of exhaust fan of size upto 300mm AC 230 Volts, 50Hz 900/1400 RPM for repair, removing existing burnt winding wire, bearing/bushes, flexible wire, shaft check nuts, frame and rewinding with super enameled copper winding wire of suitable size and weight not less than 450gms and replacement of bushes, bearings shafts, check nuts, bolts and washers, greasing, varnishing and reassembling back including testing complete:- (i) Cost of bushes/bearing/shaft provided shall be deemed to be included in quoted rates. (ii) Working space if required, will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises. (iii) If wound exhaust fan found unserviceable within six month of rewinding, contractor will repair the same without any extra cost. (iv) Cost of machining work in body of exhaust fan by taking out worn out bush, boring hole to accommodate ball bearing is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying exhaust fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard 120.00Each Job
4Supply and fix exhaust fan heavy duty made of steel complete blade fan motor with louvers, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including making good to disturbed wall surface as per existing finish complete all as specified and directed including taking down old unsv one complete all as specified and as directed.5.00Each
5Supply and fix exhaust fan heavy duty made of steel complete blade fan motor with louvers, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 450mm including making good to disturbed wall surface as per existing finish complete all as specified and directed including taking down old unsv one complete all as specified and as directed.4.00Each
13th Aug, 2026