| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Complete removal of existing treatment by scrapping with Trucare Wall Sander: L- 01/H-01 (having mechanical vacuum mechanism) or equivalent complete all as specified and directed. | 152.00 | Sqm |
| 2 | M&L for thermal insulation and composite system on internal side of existing brick wall with first layer Inner insulation layer of self-extinguishing ( Fire Grade FR-Grade ) type expanded polystyrene (EPS) insulation board of 50 mm thick (max 2.0 m x 1.0m (measured as per IS 3346-1980) density of 18 kg/cum measured as per IS 5688-1982 fire retardant properly self estinguishing ( Fire Grade FR-Grade ) type as per EN 13501-1 bonded with special adhesive polymer or polymer modified cementations adhesive confirming to EOTA 004 (European Technical Approval) formulated to bond polystyrene insulation boards to typical mineral substrata (according to ETAG 004 and polypropylene mechanical fasteners with plastic Dowel pin confirming to EOTA ETAG 014 (European Technical Approval) having dia 10mm & L= 70 mm on finished level wall and the junction between two adjacent EPS board to be seated with low expansion moisture cure polyurethane Foam. Second layer consist of Fiberglass mesh covered with alkali-resistant coating mass per unit area greater than and equal to 175 gm/Sqm. Mesh size 3.90 x 4.00mm + or - 10% embedded in special polymer modified cementations base coat with hydrophones and the corners will be protected with corner beads with alkali-resistant mesh wings at least 10 cm wide mesh mass per unit area min 175 gm/Sqm. Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50gm/Ltr and UV resistance as per IS 15489-2004. Alkali & fungal resistance, Dir resistance exterior paint of required shade (Company Depot Tinted) with silicon additives ( Two or more coat applied @ 1.43ltr/10Sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10Sqm. The surface will be levelled, finished and made smooth complete in all respect as per the manufactures specification complete all as specified and directed. | 152.00 | Sqm |
| 3 | M&L for applying 2 coat of bitumen 85/25 grade @ 1.2Kg/Sqm over existing brick wall and over thermal insulation and composite system on external side with first layer of self-estinguishing ( Fire Grade FR-Grade ) type expanded polytyrene(EPS) insulation board of 100 mm thick (max 2.0 m x 1.0m (measured as per IS 3346-1980) density of 18 kg/cum measured as per IS 5688-1982 fire retardant properly self estinguishing type as per EN 13501-1 bonded with special polymer modified cementations adhesive confirming to EOTA 004 (European Technical Approval) formulated to bond polystyrene insulation boards to typical mineral substrata (according to ETAG 004 and polypropylene mechanical fasteners with plastic Dowel pin confirming to EOTA ETAG 014 (European Technical Approval) having dia 10mm & L= 120 mm on finished level wall and the junction between two adjacent EPS board to be seated with low expansion moisture cure polyurethane Foam. Second layer consist of Fiberglass mesh covered with alkali-resistant coating mass per unit area greater than and equal to 175 gm/Sqm. Mesh size 3.90 x 4.00mm + or - 10% embedded in special polymer modified cementations base coat with hydrophones and the corners will be protected with corner beads with alkali-resistant mesh wings at least 10cm wide mesh mass per unit area min 145gm/Sqm. Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50gm/Ltr and UV resistance as per IS 15489-2004. Alkali & fungal resistance,dir resistance exterior paint of required shade(Company Depot Tinted) with silicon additives ( Two or more coat applied @ 1.43ltr/10Sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10Sqm. The surface will be levelled, finished and made smooth complete in all respect as per the manufactures specification and complete all as specified and directed. | 152.00 | Sqm |
| 4 | M&L for applying two coats of bitumen 85/25 grade @ 1.50 kg/Sqm over finished RCC Slab and over EPS sheets ( Fire Grade FR-Grade 2000mm X 1000mm X 150mm LBH )) having density 36 Kg/Cum and over heat resistant terrace tile 9300x300x20mm) laid over 20mm thick plastering in CM 1:4 and well jointed to gaps of tiles all as per manufacturer s instructions and specification complete all as specified and directed. Note- :Proper Vapour barrier with Polyethene Sheet of thickness 0.25mm shall be used before laying EPS layer. | 75.00 | Sqm |
| 5 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) and area n.exc 1.5 Sqm each complete all as specified and directed. | 9.00 | Each |