Tendering Authority: Uttar Pradesh Projects Corporation Limited
Tender ID5010543
Organisation NameUttar Pradesh Projects Corporation Limited
Tender BriefCorrigendum : Supply, Installation, Testing And Commissioning Of Smoke An Heat Extraction System, Ventilation System, Gas Suppression System At Academic Block Building At Dr. Ram Manohar Lohia Institute Of Medical Sciences,vibhuti Khand,gomti Nagar, Lucknow(u.p.)
Last Date For Submission29th Jul, 2026
Opening Date29 Jul, 2026
Cost
Document Cost17700.00
EMD1813000.00
Estimated Cost90630000.00
Location
CityLucknow
StateUttar Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply, Installation, Testing and Commissioning of Smoke & Heat Extraction System, Ventilation System, Gas Suppression System at Academic Block Building at Dr. Ram Manohar Lohia Institute of Medical Sciences, Vibhuti Khand, Gomti Nagar, Lucknow (U.P.)
2VENTILATION SYSTEM-ANIMAL HOUSE A & B BLOCK
3Axial Fan for "Exhaust Air (Emergency)"
4Supply installation, testing and commissioning of single piece long casing (Motor should completely be accommodated inside the fan casing) Vane Axial Fan (multi piece casing are not acceptable) in GSS/MS with powder coated, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE2) H Class insulation for Smoke Exhaust) suitable for 415V 10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified & Listed on AMCA website (Interpolation of pitch angle shall not be acceptable) and Fan Efficiency Grade ( Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm 2mm, Dia (700 to 1140) mm 3 mm, Dia (1200 to 1400) mm 4mm & Dia 1600 5 mm. All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade. Fan Casing should be provided with Special Designed Integral Straightening Vanes (Vanes should be integral part of casing, it should not be provided separately as an accessory) to reduced turbulence provide high performance & low noise level.
5Fans for emergency application Tube axial are to be used. Sound level for emergency operation it should not exceed 88 Db(A)@ 3 meter (Room condition).Incase of not achieving sound , attenutor has to be added. Outlet velocity of the fans should not exceed 18 m/s for emergency application.