Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4968973 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair Maint Of Ht Protection And Control System, Ht Distribution Network At Mathura Under Ge (east) Mathura |
| Last Date For Submission | 12th Aug, 2026 |
| Opening Date | 19 Aug, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 100000.00 |
| Estimated Cost | 5000000.00 |
| City | Mathura |
|---|---|
| State | Uttar Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Disconnecting & taking out 33 KV HT VCB/ SF6 Breaker of any description and any make of rating 400/630/1200 Amp, dismantling / opening of the VCB for preventive maintenance / servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and renewal of unserviceable parts with new one, re-assembling the VCB after overhauling / servicing and its testing complete and renewal of following unserviceable spare parts of make as approved by GE complete all as specified and directed. Notes :- (i) The quoted rate of contractor includes for fixing the serviceable parts in position and renewal of unserviceable parts with new parts. (ii) The new parts shall be measured and paid separately under appropriate item as supply only mentioned here-in-after (iii) Servicing to be carried out by service engineer of OEM. | 3.00 | Each Job |
| 2 | Supply only Shunt trip coil 24-30 Volts DC suitable for 33KV VCB | 3.00 | Each |
| 3 | Supply only Switch TNC (trip, neutral, close) | 3.00 | Each |
| 4 | Supply and fixing after disconnected of electric supply to VCB and replace the unserviceable Over current and earth fault protection relay, Vx=24 -240 V AC/24-250 Volt DC, In=1A/5A(0,1In-40In), Ion=1 A/5A (0,01Ion-2Lon) complete all as specified and directed. Note:- Fixing of protection relay shall be carried out through O.E.M of maanufacturer's engineer/technician only. | 6.00 | Each |
| 5 | Disconnecting & taking out 11 KV HT VCB of any description and any make of rating 400/630 Amp, dismantling / opening of the VCB for preventive maintenance / servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and renewal of unserviceable parts with new one, re-assembling the VCB after overhauling / servicing and its testing complete and renewal of following unserviceable spare parts of make as approved by GE complete all as specified and directed. Notes:- (i) The quoted rate of contractor includes for fixing the serviceable parts in position and renewal of unserviceable parts with new parts. (ii) The new parts shall be measured and paid separately under appropriate item as supply only mentioned here-in-after (iii) Servicing to be carried out by service engineer of OEM or authorised dealer | 20.00 | Each Job |