| Tender ID | 3309641 |
|---|---|
| Organisation Name | Kerala Water Authority |
| Tender Brief | Corrigendum : State Plan-state Plan 2024-25-arwss To Nooranad, Chunakkara And Adjoining Panchayaths- Wtp Pattor - Supplying And Erection Of 15 Hp C/f Pump Set At Nooranad Clear Water Sump.-general Civil Work |
| Last Date For Submission | 29th Apr, 2026 |
| Opening Date | 30 Apr, 2026 |
| Document Cost | 1840.00 |
|---|---|
| EMD | 20825.00 |
| Estimated Cost | 833017.00 |
| City | MAVELIKKARA |
|---|---|
| State | Kerala |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Appendix-A- Working charge | ||
| 2 | OD208296/2024-2025:Supply and erection of Horizontal Split Cage CF pump set with the following specification. (1) Pump (Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the plate etc. complete including providing suitable concrete foundation including cost of cement, sand and metal etc. complete. Discharge = 2300 lpm , Total Head =20 m). (2) Motor (Supply, erection testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement , sand and metal etc. complete. Flexible coupling shall be used for coupling of pumps and motors) (3) Starter (Supply ,erection testing and commissioning of suitable rating fully automatic Star Delta starter suitable for the above motor with over voltage and under voltage protection, single face preventer, over load relay with motor protection relay with main , Star, and Delta contactors of sufficient rating, timers , Interconnecting cables,Control wiring etc as per CEA regulations and code of practice etc. complete) (4) Panel board ( Suitable for operating two pump sets but one pump set at a time) (Supply ,erection testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No. Suitable capacity MCCB as incomer and 2Nos. Suitable capacity MCCB as out going ( the two MCCBs are interlocking with each other) providing suitable size Aluminum bus bar interconnect the above MCCBs and fitted with 3Nos. of indicator lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation.) (5) Cabling work (Supply , laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservations) (6) Earthing (Supply of al materials and providing suitable earthing by using suitable size pipe/plate earthing GI/Copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.) (7) Capacitor (Supply ,erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. the capacitor shall confirm to IS 2834) (8) Valves (Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works) (9) Suction and delivery pipe connection (Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.) | 2.000 | each set |
11 Days Left