Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Public Works Department
Tender ID4899524
Organisation NamePublic Works Department
Tender BriefCorrigendum : Janpad Mirzapur Stith Janpad Nyayadhish Avam Apar Janpad Nyayadhish Court Avam Chamber Me Ac Sthapit Kiye Jane Tatha Sambandhit Vidyut Wiring Ka Karya
Last Date For Submission27th Jul, 2026
Opening Date27 Jul, 2026
Cost
Document Cost2354.00
EMD975000.00
Estimated Cost15500000.00
Location
CityMirzapur
StateUttar Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1A.C. Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 0C (out door ambient temperature).1.5 TR with 5 Star BEE Rating(AC MAKE NAME- CARRIER/LG/BLUE STAR/ PANASONIC)16Nos.
2Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 0C (out door ambient temperature).2 TR with 5 Star BEE Rating(AC MAKE NAME- CARRIER/LG/BLUE STAR/ PANASONIC)61Nos.
3S/F of 4KVA Voltage Stablizer for 1.5 Ton A.C (130-280 volt) sigle phase copper winding Make -Servokon make16Nos.
4S/F of 5KVA Voltage Stablizer for 2.0 Ton A.C (130-280 volt) sigle phase copper winding Make -Servokon make61Nos.
5S/F of Suction/Discharge copper pipe line in split AC unit 1.5 ton capacity including brazing, nitile rubber insulation 9mm thick class"O" etc complete 1/4" (6.40mm) &1/2"(12.70 mm) 320Rm.
27th Jul, 2026

5 Days Left