Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4461650 |
|---|---|
| Organisation Name | Indira Gandhi Nahar Project |
| Tender Brief | Annual Repair And Maintenance Of Dfc Rest House At Canal Colony Mohangarh For The Year 2025-26 |
| Last Date For Submission | 8th Jun, 2026 |
| Opening Date | 09 Jun, 2026 |
| Document Cost | 200.00 |
|---|---|
| EMD | 5920.00 |
| Estimated Cost | 296000.00 |
| City | Mohangarh |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Providing & Fixing of 1200 mm sweep BLDC technology power saving ceiling fan which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod of 15 mm dia. ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe up to 80 cm , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Without Remote ( PWD Electrical BSR 2022 ch E-15 item no 15.4.1) | 10.00 | Each |
| 2 | Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 1.5 TR ISEER not less then 3.8 . ( PWD Electrical BSR 2022 ch E-22 item no 22.24.3) | 1.00 | Each |
| 3 | Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge | ||
| 4 | Wall mixer 3 in 1 system with provision of tetephonic bath shower with bend pipe ( PWD BSR 2022 ch S-2 item no 2.33.13) | 4.00 | Each |
| 5 | Revolving type towel ring ( PWD BSR 2022 ch S-2 item no 2.33.15) | 6.00 | Each |
6 Days Left