Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4194367
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Cwek/token-02/969 Ews/2026-27 Special Repair Of Transformers And Voltage Stabilizers Against Ber Equipments At Different Locations And Special Repair Of Ht Overhead Acsr Conductor 11 Kv Line In The Aor Of Age E/m Under Ge 969 Ews
Last Date For Submission10th Jun, 2026
Opening Date18 Jun, 2026
Cost
Document Cost1000.00
EMD103800.00
Estimated Cost5250000.00
Location
CityMulti city
StateMulti State

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply, Installation, Commissioning and testing of transformer of capacity 63 KVA step down outdoor type level-2 Copper Wounded ONAN Cooling 11/0.433 KV (at no load) AC 3 Phase 50 Hz on secondary side double wounded oil immersed naturally all air cooled with external tubes/radiator, delta connected as on primary and star connected with neutral brought on secondary side and having tapping at (+) 2.5%, (+) 5%, (+) 7.5% to be changed by hand operated OFF LOAD top changing gear. The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/LV winding when measured by the resistance method after continuous full load run in ambient temperature. The transformer shall confirming to IS 2026, 1997 and comprising of following accessories :- (a) 01 No Cable end box on HV side consisting of 03 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3 Core 95 Sqmm including cable joint complete adopter box (b) 01 No cable end box on LV secondary side consisting of 04 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3.5 Core 95 Sqmm including cable joint complete adopter box (c) Oil conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first filling of dehydrating agent. (e) Explosive vent. (f) Thermometer Pocket. (g) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI Strip. (h) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge max reading panted terminal. (j) Rating plate with terminal plate. (k) Oil drain filter valve. (l) Oil filling hole on top cover with plug. (m) Air release valve/plug. (n) 4 Nos plain solid cast steel detachable rollers. (o) Extra bushing for neutral out side the cable box providing independent earthing for neutral. (p) First fill of transformer oil confirming to relevant IS and tested upto 60KV di electric strength. 1.00Each
2Supply, Installation, Commissioning of transformer of capacity 160 KVA step down outdoor type Copper Wounded ONAN Cooling 11/0.433 KV (at no load) AC 3 Phase 50 Hz on secondary side double wounded oil immersed naturally all air cooled with external tubes/radiator, delta connected as on primary and star connected with neutral brought on secondary. The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/LV winding when measured by the resistance method after continuous full load run in ambient temperature. The transformer shall confirming to IS 2026, 1997 and comprising of following accessories :- (a) 01 No Cable end box on HV side consisting of 03 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3 Core 120 Sqmm including cable joint complete adopter box (b) 01 No cable end box on LV secondary side consisting of 04 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3.5 Core 185 Sqmm including cable joint complete adopter box (c) Oil conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first filling of dehydrating agent. (e) Explosive vent. (f) Thermometer Pocket. (g) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI Strip. (h) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge max reading panted terminal. (j) Rating plate with terminal plate. (k) Oil drain filter valve. (l) Oil filling hole on top cover with plug. (m) Air release valve/plug. (n) 4 Nos plain solid cast steel detachable rollers. (o) Extra bushing for neutral out side the cable box providing independent earthing for neutral. (p) First fill of transformer oil confirming to relevant IS and tested upto 60KV dielectric strength.1.00Each
3Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 Volts grade, of size 3 core 95 sq mm complete all as specified and directed.90.00RM
4Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.138.00RM
5Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.95.00RM
10th Jun, 2026