Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Delhi Development Authority
Tender ID3946459
Organisation NameDelhi Development Authority
Tender BriefCorrigendum : Replacement Of Outdated/ Rusted/damaged/worn-out Security Poles And Various Court Poles At Rsc And Mdcsc Dda.
Last Date For Submission16th Apr, 2026
Opening Date17 Apr, 2026
Cost
Document Cost0.00
EMD52177.00
Estimated Cost2608870.00
Location
CityMulti city
StateMulti State

Register to see full details

BOQ Items
#ItemQtyUnits
1Supplying and replacement of existing old tubular pole by HOT Dip galvanized octagonal steel pole of 10 mtr height made out of 3 mm thick sheet having bottom 210 mm A/F & top 90 mm A/F with built in connector control box with flush cover on height of 1000 mm from the bottom of pole, PCD 320 mm, MS base plate of size 320 mm x 320 mm x 20 mm thick with 250 mm strip in octagonal shape(anti theft arrangement), the pole is to be fixed on existing RCC foundation with bolt and nuts making connection, interconnection with thimble/ lugs in the connector box, earthing, making/ numbering of pole etc as required with following accessories with mounted in built in control box. a) 6 mm thick laminated sheet along with 2 nos. 6 Amp, 10KA, SPMCB, 'C' charcteristic on the din channel, 2 no. 63 Amp terminal block suitable for 25 sq.mm Aluminum condr. cable and din channel for MCB's. b) Earth stud weld at suitable height i/c washer, spring washers and nuts. c) Cable support clamps suitable for 2 nos. of 2x 16 sqmm Cable. d) Hot dipped galvanized channel type bracket suitable for mounting upto 4 nos fixture lightings with nut bolt and suitable canopy. e) Drawing of pole and bracket shall be approved from the engineer incharge as per manufacturer before use at site. ( The rate is inclusive of rebate) 25Each
2Providing and laying in position M 20 (1:2:4) reinforced cement concrete foundation of size 500 mm long x 500 mm wide and 1600 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1650mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.)-10 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-24 x 750 mm long (150 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 26 mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.)25Each
3Supplying and replacement of existing old tubelor pole by HOT Dip galvanized octagonal steel pole of 7 mtr height i/c dismantling of existing old /rusted pole, made out of 3 mm thick sheet having bottom 130 mm A/F & top 70 mm A/F with built in connector control box with flush cover on height of 500 mm from the bottom of pole , MS base plate of size 220 mm x 220 mm x 12 mm thick with 250 mm strip in octagonal shape(anti theft arrangement), the pole is to be fixed on existing RCC foundation with bolt and nuts making connection, interconnection with thimble/ lugs in the connector box, earthing, making/ numbering of pole etc as required with following accessories with mounted in built in control box. a) 6 mm thick laminated sheet along with 2 nos. 6 Amp, 10KA, SPMCB, 'C' charcteristic on the din channel, 2 no. 63 Amp terminal block suitable for 16 sq.mm Aluminum condr. cable and din channel for MCB's. b) Earth stud weld at suitable height i/c washer, spring washers and nuts. c) Cable support clamps suitable for 2 nos. of 2x 16 sqmm Cable. d) galvanized steel 500mm single arm bracket made out of suitable mm dia pipe with canopy suitable mm as required and suitable for LED fitting etc. as required. e) Drawing of pole and single arm bracket shall be approved from the engineer incharge as per manufacturer before use at site. (rebate for old dismantled MS pole is inclusive in the rate and dismantled pole shall be the property of the agency and agency should quote the rates accordingly i/c rebate )15Each
4Providing and laying in position M 20 (1:2:4) reinforced cement concrete foundation of size 400 mm long x 400 mm wide and 1400 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1600 mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.)-8 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-16 x 450 mm long (100 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 200 mm x 200 mm x 3 mm thick having 4 Nos. suitable mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.)15Each
5Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq.mm700Mtr
16th Apr, 2026