| 1 | M & L for Construction of Valve Chamber of size 1200 X 1200 X 900 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises, demolition of existing Valve Chamber of any description complete all as specified and shown on drawing No. TD/EM/06, Sheet No. 1 / 2, 2/2 and as directed by the Engineer-in-Charge. | 4.00 | Each Job |
| 2 | Design, fabrication and supply and installation of 6600 gallon (30000 ltr) capacity made with 5 mm thick MS Steel water storage tank of size 6.25 Mtr. X 3.75 Mtr. x 1.25 Mtr internal size with all accessories including roof covers, nuts, bolts, washer, bracing angle, jointing materials etc complete all as specified and directed. Different size of sections and length shall be are as under:-
Notes : (i) Nos of 5 mm thick MS plate of Size 1250 mm x 1250 mm = 31 nos
(ii) Corner angle angle iron of 65 mm x 65 mm x 6 mm thick x 1240 mm = 20 Nos
(iii) Bracing angle angle iron of 75 mm x 75 mm x 6 mm thick x 1580 mm = 12 Nos
(iv) Rafter angle angle iron of 75 mm x 75 mm x 6 mm thick x 3670 mm = 4 Nos
(v) Roof cover 1350 mm x 2600 mm x 3.15 mm thick = 03 nos
(vi) Roof cover 1310 mm x 2600 mm x 3.15 mm thick = 03 nos
(vii) Roof cover 1350 mm x 2560 mm x 3.15 mm thick = 01 nos
(viii) Roof cover 1350 mm x 1350 mm x 3.15 mm thick = 01 nos
| 4.00 | Each Job |
| 3 | (ix) All joint filled with lead wool and putty
(x) Tank should be painted internally with two coats of black bitumenous paint over a coat of primer and two caost of aluminium paint over a coat of red oxide primer externally.
(xi) Water level indicator and ladder of required height should be provided at no extra cost.
(xii) Inlet, outlet and wash out provision should be provided.
(xiii) corner Box/Joint box= 8/20 Nos
Note:-
(i) Foundation should be measured and paid separately under relevent item of BOQ.
(ii) The design and fabrication of tank shall be done in accordance with IS-804: 1967 and shall be vetted by structural Engineer of NIT/IIT/Govt Engg College and then finally approved by the GE and cost the same shall have deemed to included with unit quoted rate.
(iii) If any variation of section size and length on heigher side no price adjustment shall be entertained but if the smaller size and length shall be used, minus adjustment shall be done.
(iv) Water potabality test shall be carried out at NABL/ state govt lab. | | |
| 4 | Supply, install, fixing, commissioning and testing of TEFC mounted centrifugal type split casing pump set with CI casing, bronze impellers, C-45 shaft with pumping capacity 3500 LPM at 50 to 80 mtr head, coupler with and including energy efficieny-2 induction motor of suitable capacity and conforming to IS : 12615 , 415Volt, 3 phase, 1450 rpm to 2000 rpm-50 Hz, AC supply and suitable for drinking water including suitable size factory mild steel base frame fixed in and including foundation as per manufacturer's recommendation with nuts and bolts including anti vibration pads, painting and connection with suction & discharge water main complete with 150 mm dia foot valve at suction end, 150 mm dia NRV of size at delivery end with standard fittings and necessary electric connections with PVC insulated industrial heavy duty copper cable 16Sqmm, 3 core, 1100 volt from starter to pump set complete all as specified and as directed.Notes :- (i) Necessary foundation, base frame & bolting required for installation high pump set shall be provided as per manufacturer's recommendation and shall be measured and the cost for the same shall be deemed to be included in the rates quoted for this item.
(ii) The cost of PVC insulated industrial heavy duty cable and all other standard accessories shall be deemed to be included in the rates quoted for this item.
(iii) Foot valve and NRV should be measured and paid separately under relevent item of BOQ. | 2.00 | Each Job |
| 5 | Supplying, installation, testing and Commissioning of open well submersible pump set of 20 HP, 400 to 4800 LPM capacity, IP 68 protection, CI casing with CI motor body, CI impeller, operates at 440 volts, 3 phase 50 Hz suitable for 150mm dia delivery pipe complete all as specified and as per manufacturer's instructions and as directed by Engineer-in-Charge.
| 4.00 | Each Job |