Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4769080
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Special Repairs To Lt Panels And Connected Items At Pyro, Pinaka, Nag Mixture Building, Magazine Area And Ap Building In Hemrl, Pune
Last Date For Submission25th Jul, 2026
Opening Date01 Aug, 2026
Cost
Document Cost500.00
EMD86000.00
Estimated Cost0.00
Location
CityMulti city
StateMulti State

Register to see full details

BOQ Items
#ItemQtyUnits
1Taking out old serviceable/unserviceable LT Panel/Capacitor panel of any description or capacity keeping aside in safe custody for schedule of Credit complete all as specified and directed6.00Each Job
2Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1200 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:- Incoming: (a) ACB adjustable type with thermal magnetic release 4 pole, 800A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 Nos, (c) MCCB 4P, 125 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (d) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 200/5 - 04 Nos, (e) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (f) LED phase indicator (R,Y & B) - 01 Set. (Pyro Sub Stn)1.00Each
3Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1200 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:- Incoming: (a) ACB adjustable type with thermal magnetic release 4 pole, 800A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (c) MCCB 4P, 315 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (d) MCCB 4P, 250 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos (e) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 800/5 - 04 Nos, (e) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (f) LED phase indicator (R,Y & B) - 01 Set. (Nag Mixture Bldg)1.00Each
4Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1200 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:- Incoming: (a) ACB adjustable type with thermal magnetic release 4 pole, 800A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (c) MCCB 4P, 320 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (d) MCCB 4P, 200 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (e) MCCB 4P, 200 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos, (f) MCCB 4P, 100 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 Nos (g) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 200/5 - 04 Nos, (h) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (h) LED phase indicator (R,Y & B) - 01 Set. (Sub Stn No 34)1.00Each
5Supply, fixing and commissioning of CPRI approved factory made LT cubicle panel board Indoor type conforming to IS/IEC-61439-1&2 : 2011 with canopy, louvers & shutters made out of 2 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 1000 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:- Incoming: (a) MCCB adjustable type with thermal magnetic release 4 pole, 630 A, 415V, 50 KA, 50 Hz - 01 No. Outgoing: (b) MCCB 4P, 400 Amps, 36 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (c) MCCB 4P, 200 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (d) MCCB 4P, 63 Amps, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 Nos (e) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ratio 600/5 - 04 Nos, (f) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (f) LED phase indicator (R,Y & B) - 01 Set. (Pinaka Bldg)1.00Each
25th Jul, 2026

6 Days Left

WhatsApp