| Tender ID | 4080662 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Cwek/token-154/864 Ews/2025-26 Spl Repairs/ Renewal Of Various Capacity Distribution Transformers Against Ber In Zone A Alongwith Connnected Accessories In The Aor Of Age E/m Under Ge 864 Ews (job No W/spl Repairs (e/m)-07/bb Cantt/2025-26) |
| Last Date For Submission | 20th May, 2026 |
| Opening Date | 28 May, 2026 |
| Document Cost | 1000.00 |
|---|---|
| EMD | 103000.00 |
| Estimated Cost | 5200000.00 |
| City | Multi city |
|---|---|
| State | Multi State |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Dismantling of existing distribution Transformer fixed in 2 pole/4 pole / in plinth mounted from site with the help of crane and manpower after taking proper shut down and deposited in safe custody of MES complete all as specified and directed. | 5.00 | Each Job |
| 2 | Supply, Installation, testing and commissioning copper wound step down transformer, Indoor type complete with standard fittings, HT, 11 KV, 3 Phase, LT, 433 Volts, 3 phase 4 wire with off load tapings on Primary side to vary secondary voltage + 7.5% with tapings at every 2.5% rating of capacity 500 KVA including bushing on HT side and LT side all as per IS 1180 complete including repairing of existing plinth as per direction by Engineer in charge complete all as specified and directed. | 1.00 | Each |
| 3 | Supply, Installation, testing and commissioning copper wound step down transformer ,Outdoor type complete with standard fittings, HT, 11 KV, 3 Phase, LT , 433 Volts, 3 phase 4 wire with off load tapings on Primary side to vary secondary voltage + 7.5% with tapings at every 2.5% rating of capacity 400 KVA including bushing on HT side and LT side all as per IS 1180 complete all as specified and directed. | 1.00 | Each |
| 4 | Supply, installation, testing and commissioning copper wound step down transformer ,Outdoor type complete with standard fittings, HT, 11 KV, 3 Phase, LT , 433 Volts, 3 phase 4 wire with off load tapings on Primary side to vary secondary voltage + 7.5% with tapings at every 2.5% rating of capacity 315 KVA including bushing on HT side and LT side all as per IS 1180 complete all as specified and directed. | 1.00 | Each |
| 5 | Supply, installation, testing and commissioning copper wound step down transformer ,Outdoor type complete with standard fittings, HT, 11 KV, 3 Phase, LT , 433 Volts, 3 phase 4 wire with off load tapings on Primary side to vary secondary voltage + 7.5% with tapings at every 2.5% rating of capacity 100 KVA including bushing on HT side and LT side all as per IS 1180 complete all as specified and directed. | 1.00 | Each |