| Tender ID | 4031987 |
|---|---|
| Organisation Name | Rajasthan Rajya Vidyut Prasaran Nigam Limited |
| Tender Brief | Supply Including Fixing Of Lighting/illumination (led Lighting) At 220kv Gss, Chainpura Chhota (rajgarh) |
| Last Date For Submission | 5th May, 2026 |
| Opening Date | 06 May, 2026 |
| Document Cost | 1180.00 |
|---|---|
| EMD | 32980.00 |
| Estimated Cost | 1648649.00 |
| City | Multi city |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminum housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Compliance. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre-approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | ||
| 2 | High Power LED Flood Light Minimum lumen output 25000 lm | 35.000 | EACH |
| 3 | High Power LED Flood Light Minimum lumen output 37500 lm | 15.000 | EACH |
| 4 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-ArrmouredAluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | ||
| 5 | 4.0 Sq. mm 2 core | 1000.000 | Mtr |