Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4364767 |
|---|---|
| Organisation Name | Sher E Kashmir University Of Agricultural Sciences And Technology |
| Tender Brief | Supply, Installation, Testing and Commissioning Of Passenger Lift For Medical Centre Under Upgradation Of Existing Infrastructure Residential Quarters / Labs / Classrooms/hostels (capex) At Main Campus Shalimar Skuast-k. |
| Last Date For Submission | 2nd Jun, 2026 |
| Opening Date | 03 Jun, 2026 |
| Document Cost | 1000.00 |
|---|---|
| EMD | 79560.00 |
| Estimated Cost | 3978000.00 |
| City | Multi city |
|---|---|
| State | Jammu and Kashmir |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supply, Installation,Testing and commisioning of 15 Passenger Lift with the following Specifications as per IS:-14665 (2000) along with AMC of 3 years. capacity passenger cum bed lift Machine room less (MRL) Bed lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required :- | 1.00 | No. |
| 2 | Operating Voltage:- 415 Volts 3 Phase Hoistway size :- 1700mm X 2850 mm Pit(mm) :- 1800 Capacity (kgs) 1020 Kg, 15 persons Rise (m ) :17- 22 m Appx. 75-100 m/s STOPS: 4 Stops With (all opening on the same side) / Drive :Microprocessor Based V3F Drive. Machine : P M Gearless (Located in shaft on top of guide rails) Car Finish : Rear Mid Panel = SS Honey Comb Rear Corner Panels = SS Honey Comb Side Mid Panels = SS Honey Comb Side Corner Panels = SS Honey Comb Front Panels = SS Honey Comb False Ceiling Finish: SS Mirror Finish Hand Rail :Stainless Steel Hair Line Finish Handrails on rear car panel Ventilation:Cross flow fan Flooring:Granite Flooring /anti skid /equivalent Door Operator: DC Door Operator / Telescopic | ||
| 3 | Standard Features : (i) Speed-1.0- 1.5 MPS (ii)Floors-5(G+4) (iii) Travel-17 metres(approx) (iv) Stops & opening : 4 stops and 3 openings (v) Controller: A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. (vii) Operation: Microprocessor based single automatic push button/simplex selective collective/ duplex collective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors:- (a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). (b) Landing doors: stainless steel scratch proof . (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. (xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing 112 DELHI SCHEDULE OF RATES (E&M)-2025 doors 2 hours Fire rated, Overload detection and protection, Overs peed Governer, Dot Matrix LED D & P Indicators In Car &Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi)An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided. | ||
| 4 | Anti-nuisance Car Call Protection Control System :- Simplex automatic operation Overload Device Nudging Floor Annoucement Syatem with Music Emergency Firemen s Service Emergency Car Light Unit Infrared Curtain Door Protection Full Car Operating Panel 8 Press & Speak Phone Door Time Protection Emergency Alarm Button Extra Door Time of Lobby & Parking Door Open/Close Button Automatic Rescue Device with Dry Maintenance Free Batteries Auto Fan Cut Off Provision of CCTV Camera Fire Rating of Landing Doors for 2 Hours Floor Annuciator with Music Provision of 3 way intercom with instrument. Indicators in Car and Landings | ||
| 5 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | 12.00 | Rmt |