| 1 | Electrical Engineering Laboratory Equipment | | |
| 2 | Supply, Installation, Testing and Commissioning of Dismantling and assembling of 1- transformers setup
Product Features:
Type: Single-phase (1- ), dry-type, naturally air-cooled (AN)
Rating: 1 kVA
Frequency: 50 Hz
Voltage Rating 230V/115V, 1KVA
Installation: Indoor laboratory panel or bench-mounted
Insulation: Class B / F (as applicable)
Accessories : E& I core (laminated type).
Both primary and secondary terminal are brought out above the connection board.
| 1.0000 | no |
| 3 | Supply, Installation, Testing and Commissioning of Dismantle a DC machine Setup
Product Features:
Type: DC Motor / Generator
Rating: 1 kW (lab scale)
Voltage: Typically 220 240 V
DC Cooling: Naturally air-cooled (self-ventilated)
Mounting: Bench-mounted / base frame
Excitation: Shunt or compound (common in labs)
| 1.0000 | no |
| 4 | Supply, Installation, Testing and Commissioning of DC series motor Experimental Setup
Product Features:
DC Motor : 2HP, 220V, Series type, 1500 RPM (ISO make) 1 no.
DC starter : 2 HP capacity, 220V, 2-point starter, panel mount type 1 no.
Ammeter : 10A, MC type, DC, panel mount, 96 sq. mm 1 no.
Voltmeter : 300V, MC type, DC, panel mount, 96 sq. mm 1 no.
RPM meter : Digital type, panel mount with proximity sensor 1 no.
Rheostat : 0-100 , 8A, sliding type, cont. variable 1 no.
Motor winding Temperature protection: Digital temperature indicator with thermocouple - 1no.
The motor mounted on an MS U channel base with a flexible coupling arrangement.
The bottom portion should be fixed with an anti-vibrator pad for less vibration.
All meter mountings and fittings should be on a Class F insulation panel board with resolution
print and fittings to a powder-coated panel box and stand with a trolley mounted for easy
movement.
The panel must have an automatic cooling system for temperatures above 40 degrees. All inbuilt
connections must have markings and proper circuit diagrams with the ferule numbering system.
Patch cords and multi jacks are made of ISO make wire. All the terminals of the motors,
meters,starters etc., will be brought out on the panel for flexible connection.
User Manuals & Patch cords
| 1.0000 | no |
| 5 | Supply, Installation, Testing and Commissioning of Parallel operation of single phase transformer experimental setup
Product Features:
Transformer :1 KVA, Primary: 230 volts, Secondary : 115 volts, single phase, 50 Hz, Normally air cool 2 nos.
Variac : Single phase, Panel mount type, 0-250 volts, 10 amps (ISO make) with zero interlocking protection 1 no.
Digital Voltmeter : 0-300 volts, AC, panel type, 96 sq. mm. ISO make 2 nos.
Wattmeter: 250V/10A, digital type wattmeter, panel mount, 96sq.mm.- 1no.
Ammeter : 0-10 amps, AC, panel type, 96 sq. mm 2 nos.
Load : 0-1000watt/250 volt, bulb load-1set.
Transformer winding Temperature protection: Digital temperature indicator with thermocouple - 2nos.
All meters are mounting on a front Bakelite sheet with MS powder coated box panel and back end covered by transparent sheet for making connections visible for students.
All the terminals of the Transformer, Meters, starters etc. brought out on the panel for flexible connection. MCBs, indicators, switches brought out in the front of panel, all terminals compatible with the patch cords, connecting patch cords, circuit diagram drawn in the front panel etc.
All meter mountings and fittings should be on a Class F insulation panel board with resolution print and fittings to a powder-coated panel box and stand with a trolley mounted for easy movement.
The panel have an automatic cooling system for temperatures above 40 degrees.
All inbuilt connections have markings and proper circuit diagrams with the ferule numbering system.
Patch cords and multi jacks are made of ISO make wire.
All the terminals of the motors, meters, starters etc., will be brought out on the panel for flexible connection.
User Manuals & Patch cords
| 1.0000 | no |