| 1 | Comprehensive Routine maintenance and repair including repair/renewal/replacement of minor defective parts other than those covered under Sch A Part II of electrically operated lifts, 08 Passenger (544 Kgs) capacity fully automatic electrically operated with microprocessor based control panel, automatic operated sliding (telescopic) doors serving ground plus upper fourteen floors (G+14) installed at following bldgs including carrying out daily check and periodical service of fully automatic electric lift with power operated door Duplex full collective control system and replacement of unserviceable parts as and when required.
(A)Bearing, bushes, all type of shoes, headers, hangers, door cards, door lock
(B)Control cards, control connectors/ links, hall push button, hall push button cover
(C)Carryout jobs as and when required for rewinding of motors, welding of cracks/ broken MS parts, repair to door, safety edge working at any principle and any type of sensor
(D)Mechanical safety lock, magnetic lock or contact, cop buttons, car position indicator, door sill, car door sill
(E)Necessary wiring and cable as per requirement for safe operation of lift, lift cabin fan, cabin light including tube rod & Tube light fitting etc, complete
to ensure safety and smooth operation of lift installed at Bldg No. P-120-02 Nos complete all as specified and directed.
Make: Escon
Note : Comprehensive Maintenance / repair / replacement of all major and minor parts of elevator will be carried out by OEM only. | 22.00 | Per lift per months |
| 2 | Comprehensive Routine maintenance and repair including renewal/replacement of minor defective parts other than those covered under Sch A Part II of electrically operated lifts,02 Tonnes (2000 Kgs) capacity goods lift, fully automatic electrically operated with microprocessor based control panel, auto e doors serving ground plus upper fourteen floors (G+14) installed at following bldgs including carrying out daily check and periodical service of fully automatic electric lift with manual operated door Simplex collective control system and replacement of unserviceable parts as and when required.
(A)Bearing, bushes, all type of shoes, headers, hangers, door cards, door lock
(B)Control cards, control connectors/ links, hall push button, hall push button cover
(C)Carryout jobs as and when required for rewinding of motors, welding of cracks/ broken MS parts, repair to door, safety edge working at any principle and any type of sensor
(D)Mechanical safety lock, magnetic lock or contact, cop buttons, car position indicator, door sill, car door sill
(E)Necessary wiring and cable as per requirement for safe operation of lift, lift cabin fan, cabin light including tube rod & Tube light fitting.
Complete to ensure safety and smooth operation of lift installed at Bldg No. P-120-01 Nos complete all as specified and directed.
Make: Escon
Note : Comprehensive Maintenance / repair / replacement of all major and minor parts of elevator will be carried out by OEM only. | 11.00 | Per lift per months |
| 3 | Comprehensive Routine maintenance and repair including renewal/replacement of minor defective parts other than those covered under Sch A Part II of electrically operated lifts, 08 Passenger (544 Kgs) capacity fully automatic electrically operated with microprocessor based control panel, automatic operated sliding (telescopic) doors serving ground plus upper fourteen floors (G+14) installed at following bldgs including carrying out daily check and periodical service of fully automatic electric lift with power operated door Duplex full collective control system and replacement of unserviceable parts as and when required
(A)Bearing, bushes, all type of shoes, headers, hangers, door cards, door lock
(B)Control cards, control connectors/ links, hall push button, hall push button cover
(C)Carryout jobs as and when required for rewinding of motors, welding of cracks/ broken MS parts, repair to door, safety edge working at any principle and any type of sensor
(D)Mechanical safety lock, magnetic lock or contact, cop buttons, car position indicator, door cill, car door cill
(E)Necessary wiring and cable as per requirement for safe operation of lift, lift cabin fan, cabin light including tube rod & Tube light fitting
Complete to ensure safety and smooth operation of lift installed at Bldg No. P-121-02 Nos complete all as specified and directed.
Make: Escon
Note : Comprehensive Maintenance / repair / replacement of all major and minor parts of elevator will be carried out by OEM only. | 22.00 | Per lift per months |
| 4 | Comprehensive Routine maintenance and repair including renewal/replacement of minor defective parts other than those covered under Sch A Part II of electrically operated lifts,02 Tonnes(2000Kgs) capacity goods lift, fully automatic electrically operated with microprocessor based control panel, collapsible doors serving ground plus upper fourteen floors (G+14) installed at following bldgs including carrying out daily check and periodical service of fully automatic electric lift with manual operated door Simplex collective control system and replacement of unserviceable parts as and when required
(A)Bearing, bushes, all type of shoes, headers, hangers, door cards, door lock
(B)Control cards, control connectors/ links, haal push button, hall push button cover
(C)Carryout jobs as and when required for rewinding of motors, welding of cracks/ broken MS parts, repair to door, safety edge working at any principle and any type of sensor
(D)Mechanical safety lock, magnetic lock or contact, cop buttons, car position indicator, door cill, car door cill
(E)Necessary wiring and cable as per requirement for safe operation of lift, lift cabin fan, cabin light including tube rod & Tube light fitting.
Complete to ensure safety and smooth operation of lift installed at Bldg No. P-121-01 Nos complete all as specified and directed.
Make: Escon
Note : Comprehensive Maintenance / repair / replacement of all major and minor parts of elevator will be carried out by OEM only.
| 11.00 | Per lift per months |
| 5 | NOTE :- for Item Ser No 1 to 4
(a) The comprehensive maintenance work of lifts/waiter shall be carried out by OEM only. It is an express condition of the contract that tenders shall upload an MOU at the time of submission of technical bid in this regard with the OEM duly signed by all connected certified by registrar/ Notary and the same will be produced by the lowest tenderer in original within a week from the date of evaluation of financial bids.
(b) All above mentioned 6 (six) Lift to be inspected annually by Electrical Inspector of Lift (Govt of Maharashtra or any equivalent agency) . The contractor will be responsible for liasoning with Asstt Electrical Inspector in PWD Department for inspection of All the Lift and any Expense pertains to this is deemed to be included in the quoted rate.
(c) Every day checklist as approved by Engr in charge has to be produced by technician with the details of the individual lift.
Routine Checking / Testing /Servicing of the lift shall be done on weekly basis including greasing and oiling, if not Rs 2000 will be imposed as penalty for every week and completion of servicing to be produced to Engr in charge.
(d) Everyday one technician has to be deployed for day to day maint and rectification of faults if any and failing which Rs 1000 will be charged as penalty for every day. Technician should report its attandance to Engr in charge.
(e) Sitting arrangements for mechanic to be provided by Contractor without any claims.
(f) The technician employed should have minimum education qualification of ITI and shall have minimum 5 years experience and they should produce the attested copy of the certificates to the Engr in charge/ GE before commencement of work.
(g) The Contractor will maintain lift in good working conditions without breakdown. The tenderer is advised to maintain the rigourous maintenance schedule to avoid any breakdown and also store the spare parts (Spare parts should be as per OEM's specification) so that any breakdown is attended promptly.
| | |