Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Tata Memorial Centre
Tender ID4275659
Organisation NameTata Memorial Centre
Tender BriefSafety Improvement Works In Pump House No 1
Last Date For Submission3rd Jun, 2026
Opening Date04 Jun, 2026
Cost
Document Cost0.00
EMD82197.00
Estimated Cost4109861.00
Location
CityMumbai
StateMaharashtra

Register to see full details

BOQ Items
#ItemQtyUnits
1Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete two coat of enamal Paint .16800KG
2Depth up to 1.5mExcavation in foundation / trenches / pits drains etc. in all soils upto a required depth No.t exceeding 1.5 mtrs. Including shoring and dewatering if necessary and refilling around foundation plinth and drain line with selected excavation earth in layers Not exceeding 250mm consolidating and disposing surplus earth out of hospital premises complete all as directed by the Engineer-in-Charge.100Cum
3225mm thick Providing & laying rubble stone soling using spotless stones below floors roads/pavements etc. mechanically / manually consolidated thickness as specified below with stones vertically handset interstices packed with smaller stone chips, binding with murrum & sprinkling water for proper consolidating and finishing to required levels in quantities as and when required etc. complete all as directed by the Engineer-in-Charge.500Sqm
4PCC M10Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.60cum
5ACP :Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.5SQR
3rd Jun, 2026

Closed

WhatsApp